Trouble Shooting

Ensure all tests are undertaken by a qualified, trained engineer

Ensure safe working practices are followed at all times

PLEASE NOTE

: If the external flexible cable or cord is damaged, it shall be

exclusively replaced by manufacturer, service agent or similarly qualified person

to avoid a hazard.

Step 1: Basics

• Check polarity of Lamp connection

red=+ve, black=-ve
• Check telemetry link is in
• Check photocell is working
• Check power setting pot fully clockwise
• Check mains input
• Check fuse intact

If OK…

Step 2: Lamp Test

Check voltage of lamp o/p approx 14V (8V for pulsed units)

Check current of lamp – see instructions for correct current setting

To check lamp current (this must be done while both LED panels are connected to

the PSU) remove +ve LED from both lamp supply cables and connect multimeter

set to 10A current in line with the lamp. [One lead of multimeter in common (COM),

other lead into 10A socket of multimeter; set multimeter to 10A readings]. Refer to

PSU Specifications for correct current settings, see pages 6-7.

Step 3: Set-up Camera, lens and illumination

Check alignment of lamp

Check camera lens – fully open at night & set correctly

Check model number to Raytec performance specification to ensure required

distance is achievable