5

Trouble Shooting

Step 1: Basics

• Ensure power adjust is turned to the maximum level for troubleshooting.
• Ensure Photocell operates as required and turns lamp on and off when

covered, if necessary adjust the photocell sensitivity.

• When the light is on, a dull red glow should be visible from your

Infra-Red illuminator, and a bright white beam should be visible from

your White-Light illuminator.
• Confirm that the PoE injector, hub or switch unit is fully functioning and

is suitably rated to provide required power and suitably rated to

protocol standard 802-3af to provide power.
nB: Refer to manufacturer’s guide
• Ensure you have wired RJ45 connectors correctly at both ends.
• Check that the RJ45 waterproof connection is sound and fully weather

protected.

• Check that the cable is fully intact, and not broken or split.

Step 2: Set-up Camera, lens and illumination

Check alignment of lamp
Check camera lens – fully open at night & set correctly.
Check model number to Raytec performance specification to ensure

required distance is achievable.

Step 3: Call Raytec for further assistance

note down:
• Model and serial number of illuminator
• Camera make and model
• Lens make and model
If the Raytec lamp is still not delivering the required performance, please

contact us for further assistance: tel +44 (0) 1670 520055.

Advertising