Setra System Model LD330 User Manual

Setra local display model ld330, Installation and operating instructions, 0 i nstallation

Advertising
background image

Setra Local Display

Model LD330

Installation and Operating Instructions.

Setra’s Model LD330 is a small local display designed for convenient
in-line installation. It can be used with voltage output and current output tranducers
4-pin bayonet connectors (which meet dimensional requirements of MIL-C-26482
and the MIL STD 3116) Amp jack, 15 Pin and
9 Pin D-Sub connectors.

1.0 INSTALLATION

The LD330 can be supplied with a variety of integral electrical connectors to connect to the
mating connectors on the transducer. Consult part number chart below to determine the
proper configuration. For setting optimum viewing angle, the LD330 display housing can
rotate, at least 270 degrees, with respect to the connector. DO NOT ATTEMPT TO FORCE
ROTATIONAL ADJUSTMENT BEYOND STOP POSITION.
The LD330 is available in a variety of configurations.

1

9 PIN

15 PIN

5 PIN

CABLE

BAYONET

D-SUB

D-SUB

MINI-DIN MOLEX

CONNECTION

WIRE

PIN

PIN

PIN

PIN

+ EXCITATION

RED

A

4

7

1 2

+ OUTPUT

GREEN

B

1

2

2 1

– OUTPUT

WHITE

C

8

12

4 4

– EXCITATION

BLACK

D

9

5

5 5

CASE GND

DRAIN

SHELL

SHELL

SHELL

3 6

9 PIN

15 PIN

5 PIN

CABLE

BAYONET

D-SUB

D-SUB

MINI-DIN MOLEX

CONNECTION

WIRE

PIN

PIN

PIN

PIN

+ EXCITATION

RED

A

4

7

1

2

– EXCITATION

BLACK

D & B

9

5

4 5

CASE GND

DRAIN

SHELL

SHELL

SHELL

3 6

2.0 ELECTRICAL CONNECTIONS

The LD330 can be supplied with different style connectors to the input transducer and to
the power supply. The power supply can be supplied with cable, also. Confirm the electrical
connection supplied , and refer to the appropriate column below for
proper connections.

2.1 Voltage Units

2.2 Current Units

Advertising