SDAP Series PD 2 to PD 4 Drying and Conveying Systems

Figure 18

Setting List for Process Temperature Controller, Part No. A0555756 Cont’d.

Mode Parameter

Setting

range Default

AEC setting

Expansion

SL-H Set Point Upper

Limit

SP Lower Limit +1 to Scaling Upper

Limit

1300 400.0

Expansion

SL-L Set Point Lower

Limit

Scaling Upper Limit to SP Lower Limit -200

0

Expansion CnEL PID/ON/OFF

PID/ON/OFF

PID

Default

Expansion

SE ST Adaptive Tuning

(Fuzzy)

OFF/ON OFF

Default

Expansion SE-b ST Stable Range 0.1 to 999.9

°C/F

15 Default

Expansion ALFA

α

0.01 to 1.00

0.65

Default

Expansion

AE-G AT Calculated

Gain

0.1 to 10.0

1.0

Default

Expansion

rESE Standby

Sequence Reset
Setting Method

0/1 0

Default

Expansion

rEE Automatic Return

of Display Mode

0 to 99 SEC

0

Default

Expansion AE-H AT Hysteresis

0.1 to 9.9% FS

0.2

Default

Expansion

LbAb LBA Detection
Width

0.0 to 999.9% FS

0.2

Default


Option Boards

Available Option Boards

Option Type

RE232C

RS-485

Event Input

Transfer Output

Board Number

E53-CK01

E53-CK03

E53-CKB

E53-CKF

Mode Parameter

Setting

range

Default

AEC setting

Option Eu-A Multi-SP Function

0/1

0

Default

Option Eu-1 Event Input Assign 1

STOP/MAN

STOP

Default

Option SbCE Communication Stop Bit

½ BITS

2

Default

Option Len Comm. Data Length

7/8 BITS

7

Default

Option PrEY Commication Parity

None/Even/Odd

Even

Default

Option 6PS Comm. Baud Rate

1.2/2.4/4.8/9.6/19.2

9.6 kbps

Default

Option U-n6 Comm. Unit No.

0 to 99

0

Default

Option Er-E Transfer Output Type

SP/SP-M/PV/O/C-O

SP

Default

Option Er-H Xfer Output Upper Limit

5

5

Default

Option Er-L Xfer Output Lower Limit

5

5

Default


Note: Use the Default setting for any setting not listed here.