Chapter 7: Appendix

58 of 60

INVENTORY INFO

1.

clear_inventory,b3:0/3 (toggle this to clear all inventory, you must also reset this bit after completion)

2. hopper_inventory,f25:0
3. hauloff_accumalated_length,f31:4


EXTRUDER SETPOINT INFO
1. entered_extruder_rpm_target,f13:12 (write desired rpm here)

2. extruder_rpm_target,f13:4

3. extruder_rpm_instant,f13:1 (write rpm value here if you are not using the extruder prox signal for the

calculation, NOT FOR GH-F GRAVIMETRIC FEEDER UNITS)


HAULOFF SETPOINT INFO
1. entered_hauloff_speed_target,f18:13 (write desired line speed here)

2. hauloff_speed_target,f18:3

3. current_measured_hauloff_speed,f18:1

RECIPE SETPOINT INFO
1. entered_recipe_target,f19:1 (write desired recipe entry here such as lbs/hr,lbs/ft,lbs/ft

2

)

2. recipe_running_target,f19:0 (running target based on hopper mode)

3. recipe actual value,f19:4 (compare this to target for accuracy)
4. ext_wtp_target,f11:16 (lbs/hr or kgs/hr depending if the system is in imperial or metric)
5. ext_wtp_average,f11:3 (lbs/hr or kgs/hr depending if the system is in imperial or metric)

6. layflat,f19:3

STEADY FLAGS

1. system_stable,b50;2/5
2. extruder_rpm_stable,b50:1/14
3. extruder_wtp_stable,b50:2/0
4. hauloff_stable,b50:2/1

Alarm Number Explanation:
The alarms are given in individual bits and are reflected in the alarm number. The alarm number is only
used to drive a pop-up message and will probably not be very useful to you. If you decide to use the
alarm number instead of reading the individual alarm bits then the related values are shown below:

N26:0 Value

Alarm Description

0=

NO

ALARM

1=

HOPPER LOW LEVEL

2=

HOPPER OUT OF MATERIAL

3=

HOPPER OVER FILLING ALARM

4=

NO EXTRUDER RPM DETECTED

5=

NO EXTRUDER FLOW DETECTED

6=

HAULOFF DRIVE FAILURE

7=

LOADCELL

OVER

MAX

8=

PLC BATTER LOW Check PLC and Configure the GH Hopper

9=

PLC MODULE LOADED Turn Off Unit,Remove Module, then Configure the GH

Hopper
10=

RELOAD TOO LONG

11=

GRAVIMETRIC PERCENTAGE TOO LOW Decrease Extrusion Rate