Nominal input hp for compressors – Sterlco 30RA Outdoor Air Cooled Central Chillers 10-60 Tons User Manual

Page 5

Advertising
background image

5

Table 1C — Physical Data, 30RA — 60 Hz SI

Table 1D — Physical Data, 30RA — 50 Hz SI

LEGEND

TXV — Thermostatic Expansion Valve

*Flow switch and strainer are standard on all units, with or without hydronic package.

NOMINAL INPUT HP FOR COMPRESSORS

UNIT 30RA

010

015

018

022

025

030

035

040

045

050

055

REFRIGERANT TYPE

R-22, TXV Controlled System

Refrigerant Charge (kg)

Ckt A/Ckt B

8.2/—

12.2/—

16.3/—

16.8/—

17.2/—

21.8/—

20.0/13.6

20.4/13.6

20.0/20.0

20.4/20.4

25.0/25.0

COMPRESSORS

Scroll, Hermetic

Quantity

1

1

2

2

2

2

3

3

4

4

4

Speed (r/s)

58.3

(Qty) Ckt A

(1) SM125

(1) SM185

(2) SM110

(1) SM115,

(1) SM160

(2) SM160

(2) SM185

(1) SM115,

(1) SM160

(2) SM160

(1) SM125,

(1) SM160

(2) SM160

(2) SM185

(Qty) Ckt B

(1) SM185

(1) SM185

(1) SM125,

(1) SM160

(2) SM160

(2) SM185

Oil Charge (Compressor/L)

SM110/2.7, SM115/3.2, SM125/3.2, SM160/3.3, SM185/5.5

No. Capacity Steps

Standard

1

1

2

2

2

2

3

3

4

4

4

Optional (Maximum)

2

2

3

3

3

3

4

4

5

5

5

Minimum Capacity Step (%)

Standard

100

100

50

42

50

50

25

32

22

25

25

Optional

69

79

32

27

38

39

16

24

15

19

20

COOLER

Welded, Direct-Expansion Plate Heat Exchanger

Net Fluid Volume (L)

4.22

6.08

7.03

9.12

10.75

12.84

23.84

26.49

24.79

28.12

32.34

Maximum Refrigerant Pressure (kPa)

3103

3103

3103

3103

3103

3103

3103

3103

3103

3103

3103

Maximum Fluid Side Pressure

Without Pump(s) (kPa)

1034

1034

1034

1034

1034

1034

1034

1034

1034

1034

1034

Maximum Fluid Side Pressure

With Pump(s) (kPa)

1034

1034

1034

1034

1034

1034

1034

1034

1034

1034

1034

FLUID CONNECTIONS (mm)

Inlet and Outlet, FPT

50.8

50.8

50.8

50.8

50.8

50.8

63.5

63.5

63.5

63.5

63.5

Drain (NPT)

12.7

12.7

12.7

12.7

12.7

12.7

12.7

12.7

12.7

12.7

12.7

CONDENSER FANS

Standard Low Noise Type

Fan Speed (r/s)

Standard/Low Noise

19/9.5

19/9.5

19/9.5

—/14.2

—/14.2

—/14.2

—/14.2

—/14.2

—/14.2

—/14.2

—/14.2

No. Blades...Diameter (mm)

Ckt A/Ckt B

15...762/—

15...762/—

15...762/—

11...762/—

11...762/—

11...762/—

11...762/

15...762

11...762/

15...762

11...762/

11...762

11...762/

11...762

11...762/

11...762

No. Fans...Total kW

1...1.8

1...1.8

1...1.8

2...2.0

2...2.0

2...2.0

2...2.0 (A),

1...1.8 (B)

2...2.0 (A),

1...1.8 (B)

4...4.0

4...4.0

4...4.0

Total Airflow (L/s)

4,955

4,955

4,955

6,419

6,419

6,843

9,595

9,595

12,884

12,884

13,687

CONDENSER COILS

Quantity...No. Rows

1...2

1...3

1...3

1...3

1...3

1...3

2...3

2...3

2...3

2...3

2...3

Total Face Area (sq m)

2.14

2.14

2.14

2.97

2.97

3.72

5.11

5.11

5.95

5.95

7.43

HYDRONIC MODULE (Optional)*

Pump(s), Strainer W/Blowdown Valve, Expansion Tank, Pressure Gages, Drain and Vent Plugs, Flow Switch, and Balance Valve

Pump

Single or Dual, Close-Coupled Centrifugal Pump(s), 58.3 r/s

Expansion Tank Volume (L)

16.5

39

UNIT 30RA

010

015

018

022

025

032

035

042

045

REFRIGERANT TYPE

R-22, TXV Controlled System

Refrigerant Charge (kg)

Ckt A/Ckt B

8.2/—

12.2/—

16.3/—

16.8/—

17.2/—

20.0/13.6

20.0/13.6

20.0/20.0

20.0/20.0

COMPRESSORS

Scroll, Hermetic

Quantity

1

2

2

2

2

3

3

4

4

Speed (r/s)

48.3

Quantity — Ckt A

(1) SM160

(2) SM110

(2) SM125

(2) SM160

(2) SM185

(1) SM115,

(1) SM160

(2) SM185

(2) SM160

(2) SM185

Quantity — Ckt B

(1) SM185

(1) SM185

(2) SM160

(2) SM185

Oil Charge (Compressor/L)

SM110/2.7, SM115/3.2, SM125/3.2, SM160/3.3, SM185/5.5

No. Capacity Steps

Standard

1

2

2

2

2

3

3

4

4

Optional (Maximum)

2

3

3

3

3

4

4

5

5

Minimum Capacity Step (%)

Standard

100

50

50

50

50

25

33

25

25

Optional

71

28

31

35

37

15

25

18

19

COOLER

Welded, Direct-Expansion Plate Heat Exchanger

Net Fluid Volume (L)

4.22

6.08

7.03

9.12

10.75

21.82

24.77

21.82

24.77

Maximum Refrigerant Pressure (psig)

3103

3103

3103

3103

3103

3103

3103

3103

3103

Maximum Fluid Side Pressure

Without Pump(s) (kPa)

1034

1034

1034

1034

1034

1034

1034

1034

1034

Maximum Fluid Side Pressure

With Pump(s) (kPa)

1034

1034

1034

1034

1034

1034

1034

1034

1034

FLUID CONNECTIONS (mm)

Inlet and Outlet, FPT

50.8

50.8

50.8

50.8

50.8

63.5

63.5

63.5

63.5

Drain (NPT)

12.7

12.7

12.7

12.7

12.7

12.7

12.7

12.7

12.7

CONDENSER FANS

Standard Low Noise Type

Fan Speed (r/s)

Standard/Low Noise

15.8/7.9

15.8/7.9

15.8/7.9

—/11.7

—/11.7

—/11.7

—/11.7

—/11.7

—/11.7

No. Blades...Diameter (mm)

Ckt A/Ckt B

15...762/—

15...762/—

15...762/—

11...762/—

11...762/—

11...762/

11...762

11...762/

15...762

11...762/

15...762

11...762/

11...762

No. Fans...Total kW

1...1.8

1...1.8

1...1.8

2...2.0

2...2.0

2...2.0 (A),

1...1.8 (B)

2...2.0 (A),

1...1.8 (B)

4...4.0

4...4.0

Total Airflow (L/s)

4,130

4,130

4,130

5,349

5,349

7,995

7,995

10,737

10,737

CONDENSER COILS

Quantity...No. Rows

1...2

1...3

1...3

1...3

1...3

2...3

2...3

2...3

2...3

Total Face Area (sq m)

2.14

2.14

2.14

2.97

2.97

5.11

5.11

5.95

5.95

HYDRONIC MODULE (Optional)*

Pump(s), Strainer W/Blowdown Valve, Expansion Tank, Pressure Gages, Drain and Vent Plugs, Flow Switch, and Balance Valve

Pump

Single or Dual, Close-Coupled Centrifugal Pump(s), 48.3 r/s

Expansion Tank Volume (L)

16.5

39

COMPRESSOR

60 Hz

50 Hz

SM110

12.5

10.5

SM115

13.5

11.2

SM125

14.7

12.0

SM160

19.1

15.6

SM185

21.8

18.3

Advertising