2. Installation

The unit is designed to replace an existing single gang connection
unit, socket outlet or fixed appliance outlet. The unit is capable of
forming part of a ring main (the terminals can accept 2 x 2.5mm sq.
cables) or terminating a spur off the ring main. The unit requires a
minimum depth of 25mm within the box.
Ensure that the wiring is adequate for the load to be carried. Connect
incoming and outgoing cables to the relevant terminals. Secure the
unit to the back box with the 3.5mm screws provided forming the
cables during installation to avoid entrapment and cable damage.
Use the earth terminal in the back box for earth continuity if required.
If installed into a metal back box, earthing of the back box is
required.
There is a removable cable blank to cover the front cable exit if this
feature is not required. If front exiting cable is required use the cable
clamp supplied to secure the outgoing cable.

Fig. 2
TGBT5 Rear Connections

Neutral out

Neutral in

Cord grip/

blanking plate

fixing screw

holes

Live in

Live out