Technical data – Timeguard TR 636 top2 User Manual

Page 16

Advertising
background image

16

Technical data

• Operating voltage: 230 –240 V~, +10 %/-15 %

• Frequency:

50–60 Hz

• Power consumption: 0,8 W (TR 635 top2),

0,9 W (TR 636 top2)

• Standby:

0,9 W (TR 635 top2),

1,1 W (TR 636 top2)

• Switch output:

switching of choice of

external wires is permitted

• Contact:

two way switch

• Gap:

<3 mm (µ)

• Contact material: AgSnO

2

• Max switching capacity: TR 635 top2:

16 A, 250 V~, cos ϕ = 1

10 A, 250 V~, cos ϕ = 0,6

TR 636 top2:

6 A, 250 V~, cos ϕ = 1

6 A, 250 V~, cos ϕ = 0,6

• Min. switching capacity: 10 mA/230 V AC

100 mA/12 V AC/DC

• Incandescent lamp load + Halogen lamp load:

2300 W (TR 635 top2)

1200 W (TR 636 top2)

• Fluorescent lamp load: uncorrected +

(VVG)

series corrected 1000 VA

parallel correction 400 VA (42µF)

• Compact fluorescent lamps: 90 W

• LED lamps:

<2 W output, max. connec-

tion total of 20 W,

>2 W < 8 W output, max.

connection total of 50 W

• Permissible ambient temperature: –30 °C ... +55 °C

• Protection class: II in accordance with

EN 60730-1 subject to

designated installation

• Protection rating: IP 20 in accordance with

EN 60529

• Time accuracy:

≤ ±0,5 s/day at +20 °C

• Power reserve:

10 years (lithium call) at +25 °C

• Pollution degree:

2

• Rated impulse withstand voltage: 4 kV

• TR 635 top2:

max. switching cycles with

16 A resistive load: 50,000

• TR 636 top2:

max. switching cycles with

6 A resistive load: 50,000

Advertising
This manual is related to the following products: