Important Installation Instructions

IF IN DOUBT CONSULT AN

ELECTRICIAN.
Switch off mains electricity

Remove the existing light switch and transfer

the wires to the security switch according to

the following instructions.
If the switch is an ON/OFF two wire type,

those wires should be inserted into the

terminals marked L1 and COM. Do not disturb

any earthing wire connected to the wallbox terminal. If the switch is a 2-WAY

switch, used in conjunction with a second light switch, it will have 3 wires.

In this case the wire originally connected to the COM terminal must be inserted

into the COM terminal, the remaining two wires connect to terminals L1 and L2

in either position.

If two wires are connected to any one terminal on the original switch, these should

be kept together and inserted into the corresponding single terminal on the Digital

Security Switch. Ensure that the terminal screws are tight before refitting the unit

to the wall box and turning on the mains electricity. Lower the hinged cover, move

the slide switch to the MANUAL position and check that the rocker switch operates

the lamp normally. The unit terminals are suitable for 1mm

2

and 1.5mm

2

solid

conductors and stranded equivalents.
Note: The unit will replace any conventional single or

two way switch.

It cannot be used as an intermediate switch and cannot be used

in conjunction with a lamp dimmer in 2 way switching.