Timeguard DS3HD User Manual

Page 9

Advertising
background image

9

• Remove front panel by unscrewing the four
fixing screws.
• If necessary, carefully remove the printed circuit
board (PCB) by undoing the four PCB mounting
screws.
• Remove knockouts at (preferably) the bottom of
the box.
• Use appropriate IP65 rated entry conduits to fit
M20 knockouts. Ensure tight fitting for IP compliance.
• Fix surface mount box rigidly to a secure surface
by using appropriate screws through the four.
fixing holes.
• Refit the PCB back onto the surface mount box
by progressively tightening each of the four PCB
mounting screws in turn. Do not over tighten
the screws
• Ensuring that the mains wires are adequate
for the required load cut the cable tails to the
appropriate lengths.
• Insert mains wiring through cable conduits.
• Connect the mains wires to the mains
connector as follows:

Figure 3 - Mains supply connector

Neutral

Neutral in

Earth

Live out

Live in

Designed in the U.K. 67-058-381