Energy saver floodlight 36 watts, Installation instructions, Cont – Timeguard ECO36F User Manual

Page 2: 3 year guarantee, Catalogue number: eco36f – black

Advertising
background image

For a product brochure please contact:

Timeguard Ltd. Victory park, 400 Edgware Road, London nW2 6nD Tel: 020-8452-1112

or email [email protected]

67.058.334 (Iss.1)

A Group company

For assistance with the product please contact the HELPLINE

on 020 8450 0515 or email [email protected]

3 Year Guarantee

In the unlikely event of this product becoming faulty

due to defective material or manufacture within 3 years

of the date of purchase, please return it to your supplier

in the first year with proof of purchase and it will be

replaced free of charge. For years 2 and 3 or any

difficulty in the first year telephone the helpline on

020 8450 0515.

This guarantee does not apply to the bulb.

Energy Saver Floodlight 36 Watts

Catalogue Number: ECO36F – Black

Installation Instructions

– cont.

The bulb supplied is a class B
(high efficiency) unit of 36W power
consumption giving a similar but
more diffuse light output to the
lower efficiency 150W halogen
units previously in use.

Wiring Instructions

Connection

Remove the wiring box cover by unscrewing the 4 retaining screws
(Fig. 4) and remove the cover being careful to retain the 4 screw
sealing rings and the cover gasket.
The unit is suitable for connection to a 230 V ac 50Hz electricity
supply. An isolating switch should be installed to switch the power
to the unit on & oFF. This allows the floodlight to be easily switched
off when not required.

Rotate the flood light so that the front glass looks back towards
the wall, giving good access to the connector block.

Take out the 2 screws holding the connector block in place and
remove the connector block to ease wiring.

Connect the mains supply cable to the terminal block as follows
(see Fig. 5 connection diagram):

nEUTRAL (Blue)

n

EARTH (Green/Yellow)
LIVE (Brown)

L

Ensure the connections are secure. Replace the connector block and
replace and tighten the 2 fixing screws. Adjust any excess cable and
tighten the cable gland. Refit the wiring box cover.

*** ImpOrtaNt ***

Switch off the electricity at the consumer unit

by removing the relevant fuse or switching off the

relevant circuit breaker before proceeding with

the installation.

Fig. 4

Fig. 5

WIrINg BOx COvEr

WIrINg BOx

CONNECtION dIagram

n (blue)

L (brown)

Connector

Block

4 x Retaining screws

Cable Gland

n

E

L

supply

Internal wall
switch/circuit
breaker

E

(yellow/green

Advertising