1. General information:

Parts Included

• Luminaire unit.
• Instruction manual. Please keep safe

for future reference.

• Accessory pack.

as a fixed luminaire, and is not suitable for portable use.
The unit can get very hot during use. Ensure the unit has cooled before handling.
Ensure adequate ventilation space is allowed between the unit and any object above, in front
or to either side of the unit. Suggested space is 0.5m above, 0.3m to either side & 1.0m in front.

2. Selecting the location:

Tools & Parts Needed

• Electric or hand-held drill & bits.
• Terminal or electricians screwdriver.
• Flat and philips screwdriver.
• Wire cutters.

If you experience problems refer to Troubleshooting Guide.

If problems still exist, do not immediately return the unit to store.

Telephone the Timeguard Customer Helpline

020 8450 0515

Qualified Customer Support Co-ordinators will be on-line to assist

in resolving your query.

5. Technical specifications:

Power Supply
Lamp Type

Environmental Protection
EC Directives

230 V AC ~ 50Hz

5W LED which is the equivalent light output of a 70W
Halogen Lamp
IP55 (suitable for outdoor use)
Conforms to current EC Directives

4. Operating and testing:

Turn the power to the unit ON and the unit will illuminate.

3. Installation:

After choosing a suitable location (see previous section) install the unit as follows:

The unit is suitable for connection to a 230 V AC 50Hz electricity supply. It is suggested that

2

gauge is used. An isolating switch should be installed to switch

the power to the unit ON & OFF. This is for maintenance purposes.

Connection

Connect the cable to the terminal block as follows (see connection diagram):

NEUTRAL (Blue)

N

EARTH (Green/Yellow)

LIVE (Brown)

L

IMPORTANT

Switch off the electricity at the fuse box by removing the relevant fuse or

switching off the circuit breaker before proceeding with the installation.

Ensure the connections are secure. Refit wall plate ensuring it clicks firmly into place.

Mains

Supply

Isolation

Switch

N

L

L

N

E

Unit is for indoor and outdoor use. Unit must be mounted on a non-flammable surface

We recommend this unit be fitted by a qualified electrician. Install in accordance with wiring and
current building regulations. Please read the instructions carefully.

Pierce the grommet and pass the cable through the grommet.
Clamp the cable to the rear of the unit before securing the unit to the wall.
Fit grommet into its location hole ensuring a good seal.

Loosen up the bottom screw (Fig A). Remove wall plate by using a small flat screwdriver (Fig A) by
gently easing the wall plate outwards.

Fix the unit to the wall (Fig C). Close the rubber plug after tighten the screws (Fig E). Attach the unit
to the wall plate by a sound of click, tighten the bottom screw (Fig D). If using a power screwdriver,
use the lowest torque setting.

Class A+
6kWh/1000h
310lm typical
90x90 degrees
The lamps are not replaceable in this product

Energy Efficiency
Energy Usage
Output
Lamp Beam Angle

L

N

E

Close the rubber plug after
tighten the screws.

Open the rubber plug, mark position of the fixing holes (Fig B). Drill the holes. Insert the wall plugs