ZV810 Motion Sensor PIR
Light Switch

Please read the instructions before using the
product and retain for future use.

To avoid nuisance triggering
Your sensor switch may be activated by large
animals, lights, reflective surfaces, heat sources
or movements of objects.
The following guidelines will help you to avoid
nuisance triggering:
• Do not aim the sensor towards any light sources.
• Avoid mounting the sensor near heat sources,

such as heating vents, air conditioners, dryer
vents or lights.

• Avoid directing the sensor toward areas or

whose surfaces are highly reflective or are
subject to rapid temperature change, such as
pools.

The ZV810 can be installed at various heights
from 0.8M to 1.2M to detect a zone up to 8M in
range over a 180º angle. ( See Fig .1 )

Pattern

Item

Light

Instructions

Silver

Switch

Label

Quantity

1

1

1

Content

Coverage

6. Adjust the "TIME ", "METER" and " LUX "
knobs for "Walk Test " over the desired
detection zone. (See Fig.4)
7. Screw the inner frame in place and replace
the lifting-front cover.

Top View

SideView

More Sensitive

Less Sensitive

B. Installation procedure
1. Ensure the power supply is switched off.
2. Open the front cover, to reveal the fixing
screws (See Fig.3)
3. Loosen the screw and take apart the inner
frame.
4. Refer to wiring diagrams, for wiring
instructions.
5. Fix the motion sensor wall switch to the wall
box with screws supplied.

Fig. 3

Fig. 4

Fig. 2

Fig. 1

Installation and Wiring

This product must be wired in accordance
with the IEE Wiring Regulations. If you have
any doubt about your ability to install this
product consult a competent electrician.
Switch off the power supply before
installation and wiring.
A. Select a location
• For indoor use only ie: hallways, dining-

room, basement, utility rooms and garages,
etc. To replace existing one way or two way
light switches.

• Since the ZV810 is sensitive to temperature

changes. Avoid mounting directly above heat
sources or exposed to direct sunlight.

• Avoid mounting the motion sensor switch where

it can come into contact with water or rain.

• For best results mount the sensor switch to

detect objects moving across it. (See Fig.2)

Walk Test and Adjustment

A. Walk Test
1. After the main part of the motion sensor
switch has been fitted to the wall box turn the
power on to warm up sensor for at least
3 minutes to stabilize the sensor for normal
operation before carrying out the "Walk Test".
2. Switch the sensor switch to the middle
position for "AUTO" function. (See Fig. 11)
3. Start from outside the pattern and walk
across it until the lights come on. (See Fig. 9)
4. Adjust the sensor "METER" knob as
necessary to improve coverage until it meets
users preference. (See Fig.11)

C. Wiring Diagrams
1. To replace a one way switch.
(See Fig.5 )

2.

To replace a 2 way switch in a two way

circuit. (such as stairs), (See Fig. 6)

3.

To replace both 2

way switches in a
two way circuit.
(See Fig. 8)

• Wire dimension:

Min. 0.5mm

2

Max. 2.0mm

2

Fig. 5

Fig. 7

Fig. 8

Fig. 9

• To replace a 2 way

switch please refer
to Fig. 7 for wire
connection and add
a link to the remote
switch.

• When the Remote

Switch is actuated,
lights will remain on
for the pre-set period.

Fig. 6

Walk Test

Start Finish

3 Year Guarantee

In the unlikely event of this product becoming faulty

due to defective material or manufacture within 3

years of the date of purchase, please return it to your

supplier in the first year with proof of purchase and

it will be replaced free of charge.

For the second and third years or any difficulty in the

first year telephone the helpline on 020 8450 0515.

HELPLINE

020-8450-0515

For a product brochure please contact:

Timeguard Ltd.

Victory Park, 400 Edgware Road,

London NW2 6ND

020-8452-1112

or email [email protected]

Sensor

Mounting

Screw

Inner

Frame

Remote

Switch ZV810

ZV810

ZV810

Screw

Front

Cover

Slide

Switch

6

4

5

2

3

1

ZV810_Instructions_spreads.qxd 12/8/04 2:14 pm Page 1

Advertising