Timeguard LED400PIRB User Manual

32w led pir floodlight, Helpline, Warning

Advertising
background image

LED400PIRB.1 Instructs_147x105 7-11

31-05-12 2.58pm

7

8

9

10

A

B

24 Hrs

Lamp turns
On at night.

Lamp turns On

at day & night.

The purpose of the lens mask is to mask out areas not desired for detection.

Lens mask fi tting procedure:

• Use a penknife or pliers to cut out lens mask segment, exposing area
for detection.
• Attach the lens mask to the detector head.
• Push the lens mask for it to be locked into place.

Lens masking

Setting Advise

WARNING

3 Year Guarantee

In the unlikely event of this product becoming faulty due
to defective material or manufacture within 3 years of the
date of purchase, please return it to your supplier in the
first year with proof of purchase and it will be replaced free
of charge. For years 2 and 3 or any difficulty in the first year telephone
the helpline on 020 8450 0515.

WARNING

The temperature of the lamp is very high during operation. You will get hurt

if you touch the heat sink.

High Temperature

TECHNICAL SPECIFICATIONS:

10

20

30

40

-20

+40

10

20

30

40

Lamp adjustment

The lamp can be tilted down 55 degree and pan outward 50 degree with

the spacer or 40 degrees without.

Side View

Top View

The lamp can be tilted down 55 degree pan outward 90 degree to left

55°

50°

Spacer

50°

Spacer

90°

55°

55°

90°

The lamp can be tilted down 55 degree

and pan outward 90 degree to right.

LED lamp, PF < 0.6

LED lamp, PF > 0.9

Halogen lamp load

50W Max

200W Max

1000W Max

200W Max

Supply 220 - 240V 32W

Output 2000 Lumens

Weatherproof IP55

External Up to 5 LED 400 uncontrolled lamps

Other loads

Fluorescent tube w/o

PF correction

CFL 120W Max

32W LED PIR

FLOODLIGHT

Model: LED400PIRW - White

Model: LED400PIRB - Black

Knob Settings

LED400PIR has two adjustment knobs:

Time and Lux at the bottom of the detector head.
• Adjust knobs carefully with hand.

TIME knob setting

• Adjust the knob as desired.

LUX knob setting

• When setting the Lux knob at “MOON”, LED400PIR will only operate in

the dark.
• When setting the Lux knob at “SUN”, LED400PIR will operate in any light level.

Dusk Setting (Time knob setting)

• When setting the Time knob to “D”, the motion detector of LED400PIR won’t

function.

The lamp will operate depending on the “LUX” level, ie Dusk to Dawn..

Adjustments

Turn On time adjustment

Environment Lux level to turn On

10min

5sec

0

Min

10

0 5

sec

67.058.486

Timeguard Limited.

Victory Park, 400 Edgware Road,

London NW2 6ND

Sales Offi ce: 020 8452 1112

or email csc @ timeguard.com

For a product brochure please contact:

or email helpline @ timeguard.com

HELPLINE

020 8450 0515

• You can set the time knob from 5 sec to about 10 min, LED400PIR will turn

On the lamp, for the time duration set after each detected movement.