6

5. Technical Specifi cations

Power Supply:

230V AC 50Hz

Lamp Type:

230V 60W (max) GLS or Halogen ES

Time ON Adjustment:

1 hour – 12 hours

Environmental Protection: IP44 (suitable for outdoor use)

6. Troubleshooting Guide

The level of ambient light in the area

may be too bright to allow operation

at the current DUSK setting. During

the hours of darkness, adjust the

DUSK control slowly clockwise

until the lamp illuminates. Refer to

previous section for more details.
The level of ambient light in the area

may be too dark for the current DUSK

setting. During daylight, adjust the

DUSK control slightly anti-clockwise

until the lamp load extinguishes.

The sensor will not

operate at night.

Unit activates during

the daytime.

3 Year Guarantee

In the unlikely event of this product becoming faulty due

to defective material or manufacture within 3 years of the

date of purchase, please return it to your supplier in the first year with

proof of purchase and it will be replaced free of charge. For years 2 and 3

or any difficulty in the first year telephone the helpline on 020 8450 0515.

Note: a proof of purchase is required in all cases. For all eligible replacements

(where agreed by Timeguard) the customer is responsible for all shipping/

postage charges outside the UK. All shipping costs are to be paid in advance

before a replacement is sent.