Timeguard SLW45 User Manual

Page 5

Advertising
background image

Terminal Block

Wiring to Lantern
(see connection)

Cable Grommet

Fixing Holes

SECTION THREE

INSTALLATION

After choosing a suitable location (see previous section) install the unit as follows:

The unit is suitable for connection to a 230 V ac 50Hz electricity supply. It is suggested that
3-core round flexible cable of 1mm

2

gauge is used. A isolating switch should be installed to

switch the power to the unit ON & OFF. This allows the sensor to be easily switched off
when not required or for maintenance purposes.

Remove the lantern backplate by unscrewing the brass domed nuts. Remove the terminal
block from its mount. Punch through the knockouts in the backplate.

Mark the position of the fitting holes.

Drill the holes. Insert the rawl plugs into the holes.

PIERCE & PASS THE CABLE THROUGH THE GROMMET BEFORE PROCEEDING.

Attach the mounting plate to the wall using suitable screws. Do not overtighten the
mounting screws as this could damage the mounting plate.

Re-affix the terminal block onto the wall mounting plate.

*** IMPORTANT ***

Switch off the electricity at the fuse box by removing the relevant fuse or switching

off the circuit breaker before proceeding with the installation.

Mounting Plate