3 pir coverage, 4 installation, A installation procedure – Timeguard MLBPRO500C User Manual

Page 3

Advertising
background image

3

4

3 PIR Coverage

The MLB/WPRO500C should be installed within the height range 2.0m to 2.5m.
(See Fig. 2).

The unit has an adjustable lens with two detection zones.

• The outer zone covers an angle of 240º to a distance of approx. 3m to 16m at an

installation height of 2.3m. (See Fig. 3).

• The inner zone covers an angle of 360º which allows detection immediately

behind the MLB/WPRO500C. (See Fig.4).

• Fig. 4 also shows the variation of sensitivity with angle of approach for a person

moving within the detection area.

Fig. 2

Fig. 4

Fig. 3

Side View

2.3m

16m

240°

Min.

Min.

35°

45°

500mm

200mm

16m

16m

3m

7m

7m

4m

4m

3 4

7

3

0

Top View

Most
Sensitivity

Least
Sensitivity

4 Installation

Installation shouild only be carried out by a competent person.

Switch Off the Mains Power Supply Before Installation

The MLB/WPRO500C can be either wall mounted or corner mounted with an
adapter included with the product. (See Fig. 5).

Fig. 5

Wall Mount
Fig. 5a

Corner Mount
Fig. 5b

Corner Mounting Adapter
(See section B)

Fig. 6

Fig. 7

A Installation Procedure

a. Read the instruction manual before installing the MLB/WPRO500C.

b. Make sure the mains power supply has been disconnected.

c. Decide the best location to install the unit bearing in mind the most sensitive

direction of movement shown in Fig. 4.

Then ensure that the top of the fl oodlight is no closer than 200mm to the surface

above it and it is no closer than 500mm to the surface at the side of it.
(See Fig. 6).

Also ensure that any surface directly illuminated by the fl oodlight is at least 1m

away from the front glass. (See Fig. 8).

Do not mount the unit base on a horizontal surface such as a soffi t,

(See Fig. 7) or on an infl ammable surface such as wood or plastic.

Advertising
This manual is related to the following products: