1. Designated Use

• LEDX30PIR is an outdoor motion detector for automatic LED lighting

control.
• Mainly for wall installation.
• Simple plug in wall plate for easy & safe connection
• Suitable for a wide range of locations: corridors, gardens, staircases,
entrances, garages, outdoor parking areas etc.

Index :

Page 2

Contents and Tools required

Page 3

Connection and Installation procedure

Page 4

Installation procedure

Page 5

Sensor detection range

Page 6

Walk test & adjustment, Detector head adjustment

Page 7

Knob settings

Page 8

Lens masking

Page 9

Lamp adjustment and Warning

Page 10 Technical Specifications

18

0

1.

8

TO

2.

5

ME

TE

R

12 ME

TER

3 METER

18

0

1.8

TO

2.5

M

E

TER

12 ME

TER

3 METER

18

0

1.

8

TO

2

.5 M

E

TE

R

12 ME

TER

3 METER

10

20

30

40

40

10

20

30

40

40

10

20

30

40

40

Detection Range:

LEDX30PIR:

Recommended installation height is 2.5 meter above

ground, the maximum detection range about 12 meter and at the angle

of about 180 deg.

180°

up to12m

3m

18

0

2.5 M

E

TE

R

12 ME

TER

3 METER

180°

• Switch power on.

Detector Head Adjustment

Walk Test and Adjustment

The purpose of Walk Test is used to test and adjust the detection coverage of

LEDX30PIR under auto mode.

• Adjust the Time knob to minimum (fully anti-clockwise), then conduct a

walk test as described in test procedure.

Test procedure:

• Adjust the Time knob to (fully anti-clockwise), (Lux knob can be “Sun” or

“Moon”).

• Walk across the detection area, once the detector is triggered and the lamp
will turn ON for 2 seconds.

Note walking direction when performing test.

* Do not use the adjuster knobs to turn

the detector head.

0

2

Sec

2 sec

Dusk

Time

Test mode

Tilt down 90º

Pan left 90º

Pan right 90º

The detector head can be 90º turned left or right by hand and can be tilted
90º downward .

Installation Advise:

As the detector reacts to variations in temperature, avoid situations:

• Do not install motion detectors near heat sources such as heating outlets,

air conditioning system, lamps etc.
• Do not direct the motion detector at objects that move in the wind such

as curtains, large plants etc.
• Take account of motion direction during test run.

WARNING

• Do not direct motion detectors at objects with highly-reflective surface

such as mirrors etc.

2. Basic Safety Instruction

Danger of death through electric shock.
• Must only be installed by qualifi ed electricians.
• Avoid the metal parts of the device due to potentially high temperature.

• Designed for use in normal environments
• Intended for outdoor installation.
• Energy saving.
• Long LED lamp life time.

WARNING

• Conforms to the latest EC directives.

3. Contents:

What’s in the box?

4. Tools required:

Tools / Equipment need for installation.

INSTRUCTIONS

MANUAL

X 1

X 1

X 1

X 2

X 2

X 1

Screw:

M4x32mm

Screw peg:

6x30mm

X 2

X 4

Screw:

M3x12mm

X 1

X 1

X 1

Flat blade screw driver

Suitable for screw head

Drill bit with diameter 6mm

LIVE

BROWN

LIVE

NEUTRAL

EARTH

BLUE

GREEN / YELLOW

BROWN

Screw: M3x12mm x 4

Product’s weight:
LEDX30PIR : 1kg

Connect the cable to the terminal block as follows (see connection diagram):
Ensure the connections are secure. Refit wall plate ensuring it clicks

firmly into place.

5. Connection:

Master-Slave connection

Switch off the electricity at the fuse box by removing the relevant fuse or

switching off the circuit breaker before proceeding with the installation.

*** IMPORTANT ***

2

5

3

1

230V

4

Mounting Screws: (M4 x 32) x 2

φ 6mm

Fix the U bracket to the wall.

Switch off the power.

Drill and push the screw

peg into the hole.

Connect device

to the mains.

Unit goes into

warm-up period

for 40 sec.

10

Loosen the screws.

Attach the

wallplate

to the device.

Marking the screw hole.

12

8

Connect the individual wires to the appropriate terminal then tighten

the screws.

First, feed the cable through the

rubber gasket of the junction box.

9

11

Attach the strain relief to the

device and screw in.

Tighten the screws.

6

7

Attach the device to the U

bracket then tighten the

screws on both sides.

EARTH

LIVE

NEUTRAL

EARTH

BLUE

GREEN / YELLOW

BROWN

LIVE

NEUTRAL

EARTH

BLUE

GREEN / YELLOW

BROWN

Connect the mains supply cable to the

terminal block on the backplate as follows.

( See connection diagram )

CONNECTION

“click”

Push

Connect the cable from the lighting load to the

terminal block on the backplate as follows.

6. Installation Procedure:

Mains

Supply

N

E

L

Isolation Switch

Load

Max. wire

1 x 2.5mm per way

Max. wire

2 x 1.5mm per way

Advertising