6. Connection

Switch off the main power supply or wall switch.
Connect the mains supply cable Live core (brown) to L and Neutral core(Blue)
to N terminal.
Connect the lighting cable Neutral core (blue) to the same N terminal and Lighting
Live core (brown) to the L1 terminal on the unit (see diagram D):-
NEUTRAL (Blue)

N

LIVE (Brown)

L1 Load

LIVE (Brown)

L

Connect the Earth wire (Green/yellow) to the Earth terminal on wall box.
When wiring is complete, set the two adjustment controls on the side of the unit
(diagram C) to the following positions:

TIME – Fully anti-clockwise (Test Mode).

DUSK – Fully clockwise.

Fit the sensor unit to ceiling wall box and secure it with two fixing screws provided.