6. Connection

Switch off the main power supply or wall switch.
Connect the mains supply cable Live core (brown) to L and Neutral core (Blue)
to N terminal.
Connect the lighting cable Neutral core (blue) to the same N terminal and
Lighting Live core (brown) to the L1 terminal on the unit (see diagram D):-
NEUTRAL (Blue) N
LIVE (Brown)

L1 Load

LIVE (Brown)

L

Connect the Earth wire (Green/yellow) to the Earth terminal on wall box.
When wiring is complete, set the two adjustment controls on the side of the
unit (diagram C) to the following positions:
TIME –Fully anti-clockwise (Test Mode).
DUSK – Fully clockwise.
Fit the sensor unit to wall box and secure it with two fixing screws provided.
(Diagram E)