Connection – Timeguard SLW360L User Manual

Page 6

Advertising
background image

5

6

Mark the position of the fitting holes. See diagram G. Drill the holes.
Insert the rawl plugs into the holes.
PIERCE & PASS THE INCOMING AND OUTGOING CABLE THROUGH THE
GROMMET BEFORE SECURING CEILING MOUNTING PLATE TO CEILING.
It is recommended that the grommet is pierced with a screwdriver
to ensure a better seal.

Connection

THERE ARE 2 POSSIBLE CONNECTION SCENARIOS
1. Standard connection. See Diagram G.
The factory fitted ‘bridge’ wire must not be removed.
Connect the 4 core mains supply cable to the terminal block
on the unit as follows:-
NEUTRAL(Blue)

N

EARTH (Green/Yellow)

LIVE (Brown)

L

Connect the fourth core cable or incoming cable from the lighting load to
the L1 terminal block on the unit as follows (see connection diagram G)
SWITCHED LIVE L1
2. Switching DC loads or loads which use a different phase or voltage
supply from the AC mains. See Diagram H. Remove the factory fitted
bridge wire.
Connect the 3 core mains supply cable to the terminal
block on the unit as follows:-
NEUTRAL(Blue)

N

EARTH (Green/Yellow)

LIVE (Brown)

L

Connect the load in series with the load supply between L1 and L2
terminals.
Please note that the function of L1 and L2 can viewed as a simple switch
controlled by the PIR sensor electronics. When wiring is complete,
it is recommended that the ceiling mounting plate is fitted to the sensor
body and fixed to the ceiling as follows:-