General RCD Instructions

The RCD should form part of a 30A ring main or terminate
a spur off a 30A ring main. The cable connecting to the supply
to the RCD should be either: 2 x 2.5mm

2

for the ring main

or 1 x 2.5mm

2

for the spur.

RCD10WPV only – Fit the appropriate BS1362 fuse to suit the
load appliance to be connected.
The cable connecting the load appliance (spur only) should be
rated according to the fuse fi tted to the connection unit.
Strip sleeving and insulation and cut wires as required for the
appliance cable. Tighten the screw terminals onto the exposed
wires maintaining the correct polarity, then fi t the cable into the
cable clamp groove and tighten down the clamp box to retain
the cable.

All RCDs – Ensure that there is both suffi cient length of the
supply cable tail(s) to enable easy wiring.

Strip sleeving and insulation and cut wires as required.

Tighten the screw terminals onto the exposed wires maintaining
correct polarity and offer the unit up to the wall box, forming the
cable as required.

Screw RCD to wall box and tighten suffi ciently to hold in place.
Do not over tighten.