Timeguard TPS204 User Manual

Instructions, Tps204, 3 year guarantee

Advertising
background image

TPS204

InstructIons

3 Year Guarantee

In the unlikely event of this product becoming

faulty due to defective material or manufacture

within 3 years of the date of purchase, please

return it to your supplier in the first year with proof

of purchase and it will be replaced free of charge.

For years 2 and 3 or any difficulty in the first year

telephone the helpline on

020 8450 0515.

For a product brochure please contact:

Timeguard Ltd. Victory Park, 400 Edgware Road,

London NW2 6ND Tel: 020-8452-1112

or email [email protected]

A Group company

67-058-298

THREE YEAR

GUARANTEE

3

F I V E Y E A R

GUARANTEE

5

T W O Y E A R

GUARANTEE

2

O N E Y E A R

GUARANTEE

1

4 Operation

Always test the RCD socket outlet before use.

To test:
a RESET – press the button marked R (for reset), the status
indicator should show red, showing the socket outlet is live.
b TEST – press the red button marked T (for test), status indicator
should show black. This indicates that the RCD has tripped and
that power has been disconnected from the socket outlet.
c RESET – press the button marked R again, the status indicator
should show red.

If all the above operations work satisfactorily the RCd socket is safe
for use. If the procedure is not completed satisfactorily do not use
the RCD socket outlet and seek professional advice.

To use:
After satisfactorily testing the RCD socket outlet the appliance may
be plugged in and used in the confidence that the user is protected
by rapid disconnection from electric shock.

If the RCD trips:
Unplug the appliance. Press the button marked R and note that the
status indicator turns red. Plug the appliance back in. If the RCD
trips again, unplug the appliance and do not use, it may be faulty.
Seek professional advice.

5 Safety Issues to Remember

Electricity can be dangerous. Use of an RCD socket outlet should
not be regarded as a substitute for basic electrical safety
procedures.

Always test the rcd socket outlet before use. If the test procedure
is not completed satisfactorily, or an appliance continually trips,
unplug the appliance and seek professional advice.

To clean use a clean dry cloth only. Do not use any liquid cleaners.

Do not use outside the service conditions specified in section 3.

6 Wring Tests – Important

Remove this product from circuit if carrying out tests (as described
in the 16th edition of the IEE wiring regulations) for earth loop
impedance, prospective short circuit current and insulation
resistance.

Please use enclosed warning label to ensure this is carried out.

3 Specifications

Current rating:

13A to BS1363

Voltage:

220-240V, 50HZ AC

Rated trip current:

30mA

Trip speed:

Less than 40ms at 150mA residual

current

RCD type:

Double pole,

Suitable for 2 and 3 wire appliances

Breaking capacity:

250A (Earth leakage)

Through fault withstand:

1500A

Weatherproof rating:

IP55

Operating temperature range: -5 to 40°C

Installation temperature range: 0 to 30°C

Complies with:

BS1363 and BS7288

Conforms to directives:

73-23-EEC, 89-336-EEC

Cable capacity:

1 x 6mmsq, or 2 x 4mmsq,

or 3 x 2.5mmsq.

Connect incoming earth to socket earth terminal
Connect incoming (and outgoing) live to live terminal on RCD casing
Connect incoming (and outgoing) neutral to neutral terminal on
RCD casing
Connect socket terminal earth to earth terminal in back case if
required.