Timeguard TRT033C User Manual

Battery powered electronic room thermostat, 3 year guarantee, Cat. no. trt033c

Advertising
background image

67-058-324 (issue 3)

Battery Powered

Electronic Room

Thermostat

Cat. No. TRT033C

5. Specifications

Current rating: 3 (1) A

Voltage:

230V, 50Hz

Switch type:

Single pole, changeover

Operating

temperature
range:

0ºC to 50ºC

Set temperature
range:

10ºC to 30ºC adjustable in

0.5ºC steps

Complies with: BS EN 60730

Conforms to

directives:

Conforms to latest directives

Temperature

swing:

1ºC or 0.5ºC

Micro

disconnection: Type 1.B control action

Batteries:

2 x AA alkaline

Fig. 4

Wiring Diagram

This unit is double insulated, and hence does not

need connection to earth. If earth continuity is
required, please use earth terminal on wall plate.

To reinstall the unit on the wall plate first ensure

the wall plate retaining screws are loosened
enough to clear the TRT033C body then engage
the top of the TRT033C onto the wall plate

retaining tabs (see Fig. 3), and push firmly

downwards and then inwards. There will be
some resistance from the terminals. Once in
place, secure with the retaining screws.

Restore mains to the unit after checking all
system wiring is complete.

To insert battery, first lower hinged front
cover and lever battery holder out using the

thumbnail cut out shown in Fig. 1a.

Insert the 2 x AA alkaline batteries supplied into
the battery holder maintaining the correct polarity
as shown in the base of the battery holder.

Insert battery holder connector blades fully into
their respective slots on the TRT033C and snap

battery holder into place.

Isolate 230VAC mains supply.

Incoming and outgoing wires should be 1.5mm sq.

Remove wall plate from unit, by undoing retaining

screws (see Fig. 2), and pivoting the bottom of the
unit outwards. The TRT033C can then be lifted off.

Pass the incoming wires through the opening
in the wall plate, and fix wall plate securely to

the wall, using screws (and wall plugs if necessary)
provided. The screws which secure the TRT033C

to the wall plate should be at the bottom.

Allow sufficient excess cable to wire up the unit,
but not too much to make it difficult to close the
unit onto the wall plate.

Connect the conductors to the relevant terminals,
according to the wiring diagram below. Ensure
that the curved brass washers grip the conductors.

4. Operation

Open battery access flap and press reset.

Normally current room temperature is

displayed on the screen.

To find out or adjust the set temperature,

press the + or - button once. The screen and
button border will illuminate blue as soon as

the button is pressed until 5 seconds after the
button is released. The set temperature will

flash to show it can be adjusted. If the set
temperature is ok do nothing and the display

will return to room temperature 5 seconds later.
Otherwise use the + and - buttons to get to the

required set temperature in 0.5ºC steps. If the
+ or - button is held down, the display will

advance rapidly.

Once the desired temperature is set,
the unit will revert to displaying the
current room temperature 5 seconds after

the last button press. The illumination will
also turn off after 5 seconds.

A burner symbol is displayed when the
room temperature is below the set temperature

indicating that the thermostat is calling for heat

from the boiler.

PID control can also be turned on or off using

a jumper on the rear of the unit. PID can
minimise the temperature overshoot.

If the jumper is moved, please press reset

under battery access flap and adjust the set

temperature.

When the batteries need replacing, a battery

symbol will flash on the display.

To clean use a dry cloth only. Do not use any
liquid cleaners.

The night set back function reduces the set

temperature by about 4ºC for a given number
of hours set by the user. It is activated when
the bed symbol is flashing on the display and
the hours of set back remaining are shown on
the main display alternatively with the room

temperature.

To activate night set back press the frost/bed

button ( ) and adjust the number of hours
with the +/- button. To exit night set back,

wait for 5 seconds after any button push
(there is no blue illumination showing),
and press the frost/bed button once.

The frost function reduces the set temperature

to 5ºC. The frost function is activated by

holding down the frost/bed button for 3

seconds. The frost function is terminated by

holding down this same button for 3 seconds.

When in frost mode, the frost symbol ( ) will

flash on the display. The set temperature buttons

remain non-functional during frost mode.

The temperature swing can be adjusted

between 1ºC and 0.5ºC using a jumper found
on the rear of the unit. If the jumper is moved,

please press reset under battery access flap and

adjust set temperature.

Temperature swing – difference between on

and off switching temperatures.

For a product brochure please contact:

Timeguard Ltd. Victory Park, 400 Edgware Road,

London NW2 6ND Tel: 020 8452 1112

or email [email protected]

A Group company

HELPLINE

020 8450 0515

or email [email protected]

For assistance with the product please contact:-

3 Year Guarantee

In the unlikely event of this product becoming

faulty due to defective material or manufacture

within 3 years of the date of purchase, please

return it to your supplier in the first year with proof

of purchase and it will be replaced free of charge.

For years 2 and 3 or any difficulty in the first year

telephone the helpline on

020 8450 0515.

Note: a proof of purchase is required

in all cases. For all eligible replacements (where agreed by

Timeguard Ltd) the customer is responsible for all shipping/

postage charges for sending replacements outside the UK.

All shipping costs are to be paid in advance before

a replacement is sent.

Note:

Check boiler

instructions

before

connecting

N

NO

NC

COM

L

Advertising