Timeguard TRT036 User Manual

Operating & installation instructions, 3 year guarantee, Cat. no. trt036

Advertising
background image

7 Day Digital

2 Channel Heating &

Hot Water Programmer

Cat. No. TRT036

Operating & Installation Instructions

4. Operation

Decide whether weekday/weekend (5-2) or individual

(7) day programming is required, and move the jumper

on the rear of the product (see Fig. 2). Also move the

system jumper to either G (gravity) or P (pumped) as
appropriate for the system.
It is important to make these decisions first, as after
any change of jumper position, reset needs to be

pressed, which will return the unit to default time
and programme.
Reset
When programming a new unit or one that has been
disconnected from the mains for more than

24 hours, open the program access flap and press the

reset button (see Fig. 1a) using a pen or
similar implement which will clear the memory.

This unit is double insulated, and hence does not

need connection to earth. If earth continuity is
required, please use earth terminal on wall plate.
To reinstall the unit on the wall plate hook the top of
the unit over the retaining tabs, and push firmly back.

There will be some resistance from the terminals.
Once in place, secure with the retaining screws.
Restore mains to the unit after checking all system
wiring is complete.

These apply to every day independent of whether

weekday/weekend (5-2) or individual (7) day option
is chosen.
Note: to omit days and programmes please refer

to “Omitting days and programmes”

To change from default values, proceed as follows:-

Press set and MON will flash (with programme (P)

1 on time for heating

displayed). Press select and

P1 on hour digit(s) will flash, use

buttons to get

the required hours.
Press select and P1 on minute digits will flash,
use

buttons to get the required minutes.

Press select and P1 off hour digit(s)) will flash,

use

buttons to get the required hours.

Press select and P1 off minute digits will flash,

use

buttons to get the required minutes.

Press select and programme (P) 2 on hour digit(s)
will flash, use

buttons to get the required hours.

Press select and programme (P) 2 on minute digits
will flash, use

buttons to get the required

minutes. This procedure of alternatively using select
and

can be continued to set programmes P2

and P3.
Once complete the programmes for hot water

on

Monday can be started by pressing the set button
when MON will begin to flash and the hot water

symbol will be displayed. Press the

buttons

Omitting days and programmes
Days can be omitted by entering the same time in
each of the 3 on/off programmes for that day.
In 5-2 day mode the weekend can be omitted by using
the same technique for the 2 day (Sat & Sun) programmes.

A programme (usually P2) can also be omitted for a

given day by making the P2 on and off times the same.

This can also be applied to P1 and P3 if required.

Boost
In operating mode, there is a boost facility for

between 1 and 9 hours in one hour steps. Press the
boost button the required number of times for the

number of hours of boost required.

The programmer returns to operating mode 15

seconds after the last button push. To cancel boost,
press the boost button until 0 hrs is shown.
Press and hold the light button and the
programmer will enter holiday mode. Use the

buttons to set the required number of days. The
programmer will return to operating mode 15

seconds after the last button push. To exit holiday
mode, press and hold the light button again.

Screen illumination
Press the light button briefly at anytime,
and the screen will illuminate for 15 seconds.

5. Specifications

Current rating: 3 (1) A

Voltage:

230V, 50Hz

Switch type:

Single pole, double throw

(SPDT) for both heating and

hot water

Operating

temperature
range:

0ºC to 50ºC

Complies with: BS EN 60730

Conforms to

directives:

Conforms to latest directives

Micro

disconnection: Type 1.B control action

To clean use a clean dry cloth only. Do not use

any liquid cleaners.
Gravity System

Although the hot water may be programmed to

come on at different times to the heating, by the

nature of the system, it will also come on during all

the on times programmed for heating. This will also
be true when in boost or advanced modes.

All of the screen segments will show briefly, and then

the default programme will be displayed.
Setting time and date

To programme the current time and date,

simultaneously press and hold both the select
and set buttons for 3 seconds.

The option 12 hour or 24 hour is displayed and needs

to be set. Use the up and down buttons

to select

the required mode. Press select to move to setting the
hours. Use the up and down buttons

to set the

hour, and press select to set the minutes. Again use
the up and down buttons

to set the minutes,

and then select to set the year (y), the month (m), the

day (d), and automatic summer/winter time change or
daylight saving (dls) on/off, in each case using the up

and down buttons

. Once the time and date have

been set, press set to exit back to the operating mode.
If at any time a button is not pressed for 15 seconds,
the unit will return to operating mode.
Individual (7 day) programming on/off times

The default on/off times for heating and hot water are

as follows:
6:00 AM

on

8:00 AM

off

10:00 PM

on

12:00 PM

off

6:00 PM

on

10:00 PM

off

to get to the required day for programming,
then press select and the hot water can be
programmed as the heating above.
Having done this, heat and hot water programmes for

Tuesday can be started by pressing the set button and

selecting TUES heating using the buttons.

The three on periods for heating and hot water can

be programmed as for Monday.

Complete all 7 days in the same manner. If set is then

pressed twice the TRT036 will return to operating
mode.

This defaults to continuously off – refer to “Setting

the operating mode” to get into timed mode.
Weekday/weekend (5-2) programming on/off times
For 5-2 day mode, time periods will need to be

programmed for M-F (Mon-Fri) and then for S-S (Sat-Sun).

Only 2 sets of times need to be programmed, not 7.
Setting the operating mode
Coming out of programming, the default mode is

‘continuously off’. To enter set operating mode, press

the advance/mode button. One press changes the

output to ‘continuously on’, two presses

changes

to

‘programmed’, and three presses changes to ‘advance

to next programme’. In advance mode, once the next
time period has past, the programmer returns to

programmed mode.

For a product brochure please contact:

Timeguard Ltd. Victory Park, 400 Edgware Road,

London NW2 6ND Tel: 020 8452 1112

or email [email protected]

A Group company

67-058-327 (issue 2)

HELPLINE

020 8450 0515

or email [email protected]

For assistance with the product please contact:-

3 Year Guarantee

In the unlikely event of this product becoming

faulty due to defective material or manufacture

within 3 years of the date of purchase, please

return it to your supplier in the first year with proof

of purchase and it will be replaced free of charge.

For years 2 and 3 or any difficulty in the first year

telephone the helpline on

020 8450 0515.

Note: a proof of purchase is required

in all cases. For all eligible replacements (where agreed by

Timeguard Ltd) the customer is responsible for all shipping/

postage charges for sending replacements outside the UK.

All shipping costs are to be paid in advance before

a replacement is sent.

Advertising
Table of contents