Timeguard TRT035 User Manual

Operating & installation instructions, 3 year guarantee, Cat. no. trt035

Advertising
background image

Battery Powered

Electronic

Programmable

Room Thermostat

Cat. No. TRT035

4. Operation

Decide whether weekday/weekend (5-2) or

individual (7) day programming is required
and move the appropriate jumper on the
rear of the product.

The temperature span (difference between
on and off temperatures) can be adjusted

between 1ºC and 0.5ºC using a jumper

found on the rear of the unit.

Optimum start (switching on earlier on colder
mornings) can also be turned on or off using

a jumper on the rear of the unit.

It is important to make these decisions first,

as after any change of jumper position,

reset needs to be pressed, which will return

the unit to default time and programme.

Pressing any button illuminates the screen

automatically.

During time/date and programme setting if

a button is not pressed within 15 seconds the
display will revert to the start of the sequence.

5. Specifications

Current rating: 3(1)A

Voltage:

230V, 50Hz

Switch type:

Single pole, change-over (SPCO)

Operating

temperature
range:

0ºC to 50ºC

Set temperature
range:

10ºC to 30ºC adjustable in

0.5ºC steps

Complies with:

BS EN 60730

Conforms to

directives:

Conforms to latest directives

Span:

1ºC or 0.5ºC

Micro

disconnection:

Type 1.B control action

Batteries:

2 x AA alkaline

Setting date and time of day

Open programme access flap and press reset,
using a pen or similar object. All of the screen

segments will show briefly, and then the current
room temperature will be displayed.

To programme the date and time of day, open

programme access flap, and simultaneously
press and hold both the select and set buttons

for 3 seconds. The year will flash.

Use the + and - button to set the correct year.

Press select to move on to programming the
month (shown to the left), and then again

to programme the day. Press select again to
programme the hours (am/pm), and again

to programme the minutes (each time using
the +/- button to make the change). Press set

to return to operating mode.

If at any time a button is not pressed for

15 seconds, the unit will return to operating mode.

Programming temperature periods for
7 days option

Notes

1) There are no off periods with this controller.

The programming sequence is:

Start time, temperature, second start time,

second temperature and so on. Setting

temperature to 10ºC is as close to off as can
be achieved (and for most situations will be

off unless the weather is very cold).

2) If you do not want a higher temperature

period in the middle of the day adjust the

temperature for this period downward to
match those of the proceeding and

subsequent period temperatures.

3) The TRT035 comes with a factory installed

(default) programme for both 5-2 and 7 day
options which you use or modify as you

wish. Just pressing the reset button brings
this programme into operation.

The default programme for every day is as
follows:-

6:00 AM

21ºC

8:00 AM

17ºC

12:00 PM

21ºC

2:00 PM

17ºC

4:00 PM

21ºC

10:00 PM

17ºC

For both 5-2 and 7 day options.

To programme the temperature periods, press

the set button. Mon will flash. To programme
Mondays time/temperature periods press select

button. Alternatively use the + and - buttons to

change the day, and then select to continue.

The time will then flash. This is the start time

for the first period. Press + or - to set the hour

for the start time for period 1. Press select to

move to the minutes. Use the + and - to set the

minutes. Press select to set the temperature for

this period. Use the + or - keys to set the
desired temperature. Press select again to
programme the next time period. There are
6 time periods per day.

Once the 6 periods for Monday are
programmed, Press set button, and Monday
will start to flash. Use the + and - button to

change the day to Tuesday, and then use select
to programme Tuesdays time periods and

temperatures. For 7 day programming, this will
need to be done for all 7 days. If set is pressed

twice, the unit will return to operating mode.

Omitting Days

Omitting a day can be achieved by selecting
10ºC for every time period for that day
(all times and temperatures must be entered).

The heating will not turn on unless the room
temperature falls below 10ºC (50ºF).

Programming temperature periods for
5-2 days option

For 5-2 day mode, time periods and

temperatures will need to be programmed for
M-F and then for S-S. ie: only 2 sets of times

need to be programmed, not 7 (individual) sets
of times.

Temperature override

In operating mode, the temperature set for the
current period can be overridden. To adjust the
set temperature, press the + or - button once.

The screen will illuminate blue while button
is pressed. Use + and - buttons to set desired
temperature. If the + or - button is held down,
the display will advance rapidly. Once the

desired temperature is set, the unit should
revert to displaying the current room

temperature 5 seconds after the last button
press. The illumination will also turn off after

5 seconds. In manual mode, there will be a
hand symbol displayed on the screen. The new
temperature will remain valid until the next

programmed period starts.

A burner symbol is displayed when
temperature is below desired value, indicating

that the thermostat is calling for heat from
the boiler.

Review set temperature

The set temperature can be reviewed at any
time, by a single press of the + or - button.

5 seconds after this single button push, the unit
will show the current room temperature, and

the screen illumination will turn off.

Frost protection

Frost protection reduces the set temperature to
5ºC. Frost protection is activated by holding
down the frost protection button for 3 seconds.

When in frost mode, the frost symbol will
flash on the display. The set temperature
buttons remain non-functional during frost
mode. The unit will remain in frost mode

until the frost button is held down for a
further 3 seconds.

Battery replacement

When the battery needs replacing, a battery
symbol will flash on the display.

Sleep mode

The unit can be put into sleep mode by
simultaneously holding down the + and -

buttons for 3 seconds. Pressing any button

will exit sleep mode. In sleep mode, all

outputs are suspended and the screen is blank

(useful for longer periods when the house is
unoccupied and frost protection is not required).

To clean use a dry cloth only. Do not use any
liquid cleaners.

Operating & Installation Instructions

For a product brochure please contact:

Timeguard Ltd. Victory Park, 400 Edgware Road,

London NW2 6ND Tel: 020 8452 1112

or email [email protected]

A Group company

67-058-326 (issue 2)

HELPLINE

020 8450 0515

or email [email protected]

For assistance with the product please contact:-

3 Year Guarantee

In the unlikely event of this product becoming

faulty due to defective material or manufacture

within 3 years of the date of purchase, please

return it to your supplier in the first year with proof

of purchase and it will be replaced free of charge.

For years 2 and 3 or any difficulty in the first year

telephone the helpline on

020 8450 0515.

Note: a proof of purchase is required

in all cases. For all eligible replacements (where agreed by

Timeguard Ltd.) the customer is responsible for all shipping/

postage charges for sending replacements outside the UK.

All shipping costs are to be paid in advance before

a replacement is sent.

Advertising
Table of contents