Timeguard TRT039 User Manual

Electronic 3 and 4 channel programmers, Operating & installation instructions, 3 year guarantee

Advertising
background image

The programmer comes with default on/off times

for each channel. These are:
Mon to Fri

Period 1, on at 6.30, off at 8.30
Period 2, on at 12.30, off at 12.30

Period 3, on at 17.00, off at 22.00.
(There is no programme 2).
Sat to Sun
Period 1, on at 8.00, off at 10.00

Period 2, on at 12.30, off at 13.30
Period 3, on at 17.00, off at 23.00
The default date is 1st January 2008,

and the default time is 00.00.

Programming:

At any time during programming, the unit will

return to the operating mode if a key is not

pushed for a period of 1 minute.

When programming a new unit, press the reset
button, using a pen or similar implement, which

will clear the memory. For subsequent programme
changes resetting will not usually be necessary.

To set the correct time and date, open the right
hand flap to access the programming buttons.

Press the green menu button.

Use the + and - buttons to move the blue bar to
settings, and press enter.

Use the + and - buttons to move the blue bar to
time and date and press enter.

Use the + and - buttons to set the hour,
press enter, and use the + and - buttons to

set the minutes, and press enter.

Then using the + and - buttons, set the date,

press enter, set the month, press enter and then
set the year.

Press menu to return to the programming screen,

and again to exit programming.

In menu settings, automatic daylight saving can
be disabled, (it is automatically enabled as a

default), and in clock options, 24 hour or am/pm

can be selected as a preference.

Changing channel headings:

The channel headings can be changed in menu >

settings > headings. The options available are:

3 channels heating, 1 channel hot water.

2 channels heating, 2 channels hot water.

Zones (zone 1, zone 2, zone 3, zone 4).

Channels (chan 1, chan 2, chan 3, chan 4).

The current selection is indicated by < > around

the words. Move the blue bar to highlight the

required selection, and press enter. Pressing menu
will return to previous menu listing, and pressing
menu again will return to operating mode.

The default setting is channels.

Setting programme times:

Press menu, and then move the blue bar to
highlight the desired channel. Press enter to accept

that channel, and then use the + and - buttons to
select the desired day to programme. Once the

desired day is shown, press enter to access the
programme times.

To change period 1 on, use the + and - buttons to
change the on time in 10 minute steps. Holding the

+ or - enables the time display to increment or
decrement rapidly. Once the correct on time is set,
press enter to move to programming the off time

for period 1.

Use the enter key to accept the times for the

other periods, once they have been adjusted to
the desired value.

Accepting the off period for period 3 will return

the screen to the choose day option, and will index
on to the next day. Now press enter and the channel

1 times will be displayed ready for programming.

There is a copy button, which can be used to copy

settings from one day to another. Once say Monday

channel 1 has been set, when the switching
times for the next day (Tuesday) are displayed,
press copy once, and it will copy the

Electronic

3 and 4 Channel

Programmers

Cat. No. TRT038 (3 channel),

TRT039 (4 channel)

Operating & Installation Instructions

TRT038 (3 channel)

TRT039 (4 channel)

14:23

Advance

Boost

Advance

Boost

Advance

Boost

Advance

Boost

HTG 1

0FF

0FF

HTG 2

ON until

WATER

ON until

Monday

25 Feb

HTG 3

Auto

22.30

Auto

22.30

14:23

Advance

Boost

Copy

Enter

Over

-ride

Advance

Boost

Advance

Boost

Menu

Reset

Advance

Boost

HTG 1

0FF

0FF

HTG 2

ON until

WATER

ON until

Monday

25 Feb

HTG 3

Auto

22.30

Auto

22.30

4. Operation

The TRT038/9 has a back lit LCD matrix display,

which shows the 3/4 channel names and their

status (back lighting occurs when any button is
pressed). It shows the current day/date, and the
current time. There is a suitcase symbol displayed

if the unit is in holiday mode.

Channel

indicator

Output

status

Day

Date

Heating 2

off time

Clock

time

Holiday

indicator

5. Specifications

Current rating:

3 (1) A

Voltage:

230V, 50Hz

Operating temperature
range:

0ºC to 50ºC

Complies with:

BS EN 60730

Conforms to directives: Conforms to

latest directives

Micro disconnection:

Type 1.B control action

Battery back-up:

24 hour, rechargeable

programme settings from Monday to Tuesday.

The display will briefly show the set times, and
then revert to set channel 1 for Wednesday.
Press copy again to copy Tuesdays settings to
Wednesday if required.

Setting holiday mode:

The holiday mode suspends programmed operation

for the set period. It operates from midday on the
selected day of departure, until midday on the

day of return. Once out of holiday mode, the

programmer returns to its pre-programmed state.
In holiday mode a suitcase symbol is displayed

on the screen.

It can be accessed by pressing menu, using - to

select “set holiday mode” and then pressing

enter. The start and end date can be programmed
using the +, -, and enter buttons.

Once in holiday mode, it can be cancelled by
changing the end date to the current date.

Programme overrides:

Each channel can be individually overridden,
using the blue override buttons.

The options available are:

Auto (default setting) - follows programmed times.
All day – Programme starts at first on time, and is

on until third off time.

ON - Constantly on until override is removed.

OFF - Constantly off until override is removed.

The override option scrolls with each press of the

override button. Once the selected override is no
longer required, use the override button to scroll

to auto mode, to return to programmed times.

Boost function:

The boost function can be used to turn a channel

on for a period of 1 or 2 hours, or it can extend

an on period by 1 or 2 hours if the channel is
already on. In boost mode, the boost button

remains illuminated for the duration of the
boost period.

If boost is used to turn a channel on, and the
program for that channel would turn it on during
the period of the boost, then the end time

displayed will be the end of the programmed
time, not the boost time.

Press boost once for one hour, twice for two
hours, and 3 times to cancel.

Advance function:

The advance function will advance the program

to the next change. If it is currently off, it will
turn on, until the next turn off time. If it is

currently on, it will turn off, until the next

programmed on time. The advance button will

remain illuminated until the next change of state.

Resetting the TRT038/9:

Press the reset button under the front flap to reset
the factory settings.

General information:

The TRT038/9 is fitted with a non user serviceable

battery, which will retain programmed information
and time/date for 24 hours in the event of a power

cut. During this time, the screen will be blank.
It will come back on once power is restored.

For a product brochure please contact:

Timeguard Ltd. Victory Park, 400 Edgware Road,

London NW2 6ND Tel: 020 8452 1112

or email [email protected]

A Group company

67-058-329 (issue 2)

HELPLINE

020 8450 0515

or email [email protected]

For assistance with the product please contact:-

3 Year Guarantee

In the unlikely event of this product becoming

faulty due to defective material or manufacture

within 3 years of the date of purchase, please

return it to your supplier in the first year with proof

of purchase and it will be replaced free of charge.

For years 2 and 3 or any difficulty in the first year

telephone the helpline on

020 8450 0515.

Note: a proof of purchase is required

in all cases. For all eligible replacements (where agreed by

Timeguard Ltd) the customer is responsible for all shipping/

postage charges for sending replacements outside the UK.

All shipping costs are to be paid in advance before

a replacement is sent.

Advertising
This manual is related to the following products: