Testing a Loop tester

Loop testers measure the resistance of the mains supply. The measurement is made in Ohms.

1: Plug the 2080 into an Unprotected supply (no RCD trip) and plug the loop tester into the Left-hand
socket ‘LOOP’ on the 2080 as shown below.

NOTE IF A LOOP TEST IS PERFORMED WHILE PLUGGED INTO THE RCD SOCKET
THEN THE FUSE ON THE FRONT OF THE 2080 WILL BLOW.

2: Set Loop Test switch to the ‘SUPPLY LOOP’ position (LEFT) on the 2080. Select the

Lowest range on the tester and press the test button on the loop tester. Note the reading.

3: Switch to the ‘LOOP + 1R’ position on the 2080, and press test again on the tester.

Record the difference from the reading above.
Allow readings from 0.9 Ohms to 1.1 Ohms ± 1 digit.

** Many testers have both a normal measurement mode, and a ‘no trip’ mode.
Readings should be taken for both modes.

Common Problems

Solution

No Power to Loop Tester

1: 2080 not plugged into supply
2: Faulty loop tester mains lead

Unstable reading on tester

Noise on mains supply - try a different
mains socket for the 2080

Supply trips out when test button pressed

2080 must be used on unprotected supply

The allowance figures given in this application note are based on a typical ‘working’ accuracy for a
tester when used with the 2080, and are given as guidelines for the purpose of checking for correct
operation of a 16

th

edition instrument. Many testers may give better accuracy, which will be tested

against manufacturers specification on a full calibration.

2080 Specifications Summary

Continuity Testing

0.5

Ohms

: 2

Ohms

: 10

Ohms

1% ± 20m

Ohms

Max. Current : 300mA

Insulation Testing

1M

Ohms

: 9.9M

Ohms

: 99M

Ohms

: 1% Max. Test Voltage 1.2kV

RCD Testing

10mA (Nominal) @150ms • 30mA (Nominal) @ 150ms • 150mA (Nominal) @ 30ms

LOOP Testing

Supply Loop • Supply Loop + 1

Ohm

: 5%