Default ATYPE Confi guration:

Axis 0: Voltage output servo axis with encoder feedback ATYPE AXIS(0)=2

Axis 1: Encoder feedback axis for synchronisation

ATYPE AXIS(1)=3

Stepper Confi guration:

Axis 0: Step and direction differential outputs

ATYPE AXIS(0)=1

Axis 1: Step and direction differential outputs

ATYPE AXIS(1)=1

Stepper/Encoder Confi guration:

Axis 0: Encoder feedback axis for synchronisation

ATYPE AXIS(0)=3

Axis 1: Step and direction differential outputs

ATYPE AXIS(1)=1

Changes to ATYPE should be set prior to enabling the axes with WDOG=ON.

This statement should ideally placed in the STARTUP program. See user

manual for other ATYPE combinations.

An internal relay (Enable A and Enable B) is used to enable external
amplifi ers when the controller has powered up correctly and the system
and application software are ready. The amplifi er enable is a single pole
solid state relay with a set of normally open volt free “contacts”.

ALL STEPPER AND SERVO AMPLIFIERS MUST BE INHIBITED WHEN
THE AMPLIFIER ENABLE OUTPUT IS OPEN CIRCUIT

AMPLIFIER

ENABLE

(WATCHDOG)

RELAY OUTPUT