Fuse Replacement
The fuse is in series with the “OHM” input jack. If this fuse is open the
OHM circuit will not work. When replacing the fuse be sure to replace it
with a fuse of the same current rating and internal resistance. The use
of a fuse with a different internal resistance may cause the accuracy of
thee “OHMS” scale to be off. Remove the screws in the rear of the case
for access to the fuse. Fuse should be 0.3 Amp / 0.9 OHM resistance.

Mechanical Zero Adjust
The pointer is set to register 0 at the left edge of the scale when there
is no input to the MCP9A and it is laying face up on a flat surface. If
the pointer does not register 0, it may be reset to that position by
carefully adjusting the black screw in the meter face, just below the
LOCK” switch.

S p e c i f i c a t i o n s

Optional Accessories

Optional
Battery 1.5V, size “AA” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .AB1
Fuse 0.3 Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .AF45
Test leads ACV, twist lock (pr) . . . . . . . . . . . . . . . . . . . . . . . . . . .ATL30
Test leads OHMS, twist lock (ea) . . . . . . . . . . . . . . . . . . . . . . . . .ATL35
Alligator clip adapters, insulated (pr) . . . . . . . . . . . . . . . . . . . . .AAC
Plug-in line splitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ASL1

MCP9A-MAN

P. 3

Ranges

AC Amps

0 - 6, 15, 40, 100, 300A

AC Volts

0 - 150, 300, 600V

OHMS

1KΩ (20Ω center scale)

Accuracy

AC Amps

±3% of full scale

AC Volts

±3% of full scale

OHMS

±3% of scale length

General

Jaw opening

1 - 1/4”

Battery

One 1.5 V, size “AA” (NEDA #15D) battery supplied

Fuse

0.3 Amp 0.9 OHM

Size

8 - 1/8” x 3 - 1/8” x 1 - 1/2” (206 mm x 79 mm x 38 mm)