Operating Instructions

Auto power off
After powering off, the meter will turn back on if you perform one of
the following; Change the range, move the position of the selector or
any other button is pressed. NOTE APO is disabled while in MIN/MAX
mode.

Back-light / work area light(DL379 / DL389 only)
Press the “HOLD” button longer than two seconds to activate the
backlight/work area light. The lights automatically turn off after 2
minutesto extend battery life.
NOTE: After activating worklight, press briefly to activate hold.

Auto / Manual Range
In auto range the meter will select the best range for the measured
value, and "AT" is displayed. Press the "RANGE" button to cycle
through available ranges. “AT” will not be on the display when locked
in a specific range. Press and hold ”RANGE” button to return to auto
range.

MIN/MAX mode
When using the MIN/MAX capture mode for Amps, it is recommended
that you first select the range of the expected maximum value. If this
is not done it will lock in the lowest range possible for the initial
measurement. If the maximum value exceeds this range the meter will
capture “O.L” as the maximum value.

Manual ranging will also provide a faster response to the input.

Data Hold
Press the “ “ button to activate. This will freeze the reading and
range in the display for your review.

Maintenance

Periodic Service

WARNING!

Repair and service of this instrument is to be performed by qualified
personnel only. Improper repair or service could result in physical
degradation of the meter. This could alter the protection from electrical
shock and personal injury this meter provides to the operator. Perform
only those maintenance tasks that you are qualified to do.

Cleaning
Periodically clean your meter’s case using a damp cloth. DO NOT use
abrasive, flammable liquids, cleaning solvents, or strong detergents as
they may damage the finish, impair safety, or affect the reliability of
the structural components.

Battery Replacement
Remove screws from battery compartment cover on back of meter
and remove cover. Replace batteries with fresh batteries paying
attention to polarity position. Replace cover and screws.

Limited Warranty

The DL369/DL379/DL389 is warranted to be free from defects in
materials and workmanship for a period of three years from the date of
purchase. If within the warranty period your instrument should become
inoperative from such defects, the unit will be repaired or replaced at
UEi’s option. This warranty covers normal use and does not cover
damage which occurs in shipment or failure which results from
alteration, tampering, accident, misuse, abuse, neglect or improper
maintenance. Batteries and consequential damage resulting from failed
batteries are not covered by warranty.

Any implied warranties, including but not limited to implied warranties
of merchantability and fitness for a particular purpose, are limited to the
express warranty. UEi shall not be liable for loss of use of the instrument
or other incidental or consequential damages, expenses, or economic
loss, or for any claim or claims for such damage, expenses or economic
loss. A purchase receipt or other proof of original purchase date will be
required before warranty repairs will be rendered. Instruments out of
warranty will be repaired (when repairable) for a service charge. Return
the unit postage paid and insured to:

1-800-547-5740 • FAX: (503) 643-6322

Service: (800) 308-7709
www.ueitest.com • Email: [email protected]

This warranty gives you specific legal rights. You may also have other
rights which vary from state to state.

0.44V

Slide temperature switch
down prior to connecting
probe.

NOTE If The backlight / worklight
is on, the worklight will turn off
during NCV tests.

Temperature Adjustment

Remove battery cover.
Place temperature probe in a
known standard. (Stirred crushed
ice in distilled water can be used for
32ºF)

Adjust potentiometer with a
fine tip standard screwdriver to
match the display to 32ºF.

NOTE: The adjustment for the
potentiometer is accessible
throughthe lower right access
port under the battery cover.

• Select any function to power
the upper display.

• Press “MAX/MIN” to activate
Max capture, Min capture, or
normal display.

NOTE: Max capture is useful
for motor in rush current.

Attaching/ Detaching Clamp Head

To detach clamp head first unplug all leads and probes. Firmly
grab clamp head and pull apart. When attaching a clamp head or
attachment, align heads and push together ensuring the
heads lock securely.

NOTE: Leaving clamp head or attachment plugged in will
drain battery.