TP6K K-Type Bead Thermocouple (a standard accessory)

Electrical

17

Type

K-Type, Chromel Alumel, bead style

Temperature range

-40˚ to +900˚F (-40˚ to +480˚C)

Accuracy

±2.0˚F (±1.1˚C)

Measurement range

J-Type: -346˚ to +2192˚F (-210˚ to +1200˚C)

K-Type: -328˚ to +2498˚F (-200˚ to +1370˚C)

T-Type: -418˚ to +752˚F (-250˚ to +400˚C)

E-Type: -238˚ to +1832˚F (-150˚ to +1000˚C)

Display Resolution

0.1˚F/˚C < 1000˚

1.0˚F/˚C ≥ 1000˚

Measurement

J, K, T, and E-Type; ±[0.1% +1.0˚F (0.5˚C)]

Accuracy

[Below -148˚F (-100˚C): add 0.2% of reading

for J, K, and E-Type; and 0.1% of reading for

T-Type]

Temperature

0.01% of reading 0.1˚F per ˚F(+0.05˚C per ˚C)

Coefficient

for <+64˚F (+18˚C) or +82˚F (+28˚C)

[Below -148˚F (-100˚C): add 0.05% of reading

for J, K, and E-type; and 0.1% of reading for

T-type]

Real Time

About 1 second per day

Clock Tolerance

Maximum Differential

1V (maximum voltage difference between

Common Mode

any pair of inputs)

Voltage

Temperature Scale

ITS-90 (International Temperature Scale

of 1990)

Applicable Standards

N.I.S.T. Monograph 175 revised to ITS-90

Accuracy is specified for ambient temperatures between 64˚F (18˚C)

and 82˚F (28˚C) for a period of 1 year. The above specifications do not

include thermocouple error.