Maintenance

Typical maintenance of the UVPhotoMAX™ system includes recommended

annual service and the replacement of the Dual Spectrum UV Lamp. UV

lamps undergo a photochemical process during operation that slowly

reduces the amount of germicidal UV light generated.

When installing new lamps, ensure that the lamp glass is free from any

fingerprints or debris, as this may alter the path of the UV energy. Use

rubbing alcohol and a dry cloth to remove any surface contaminants.

7

Adjusting the Photon Clarifier

The UVPhotoMAX™ is a universal air

purifier with a patented design that provides

adjustability to the advanced photocatalytic

process for a variety of treated space sizes.

When setting up your equipment, adjust the

Photon Clarifier Adjuster (under electronics

cover) to the appropriate position based on

the square footage of the home or CFM of

the air handler.

Fine adjustments may be required

depending upon household living characteristics.

For more information please call Ultravation Customer support at

1-866-468-8247.

500

1000

2000

2500

3000

3500

4000

4500

5000

10000

6000

7000

8000

9000

2000

4000

5000

3000

1000

CFM

Sq. Ft.

Photon Clarifier

Adjustment

Service Indicator Reset

1. To set or reset the Bi-Annual Service Indicator the unit

must be connected and have power.

2. Press and hold the square yellow RESET button for 10

seconds using a non-metallic implement. The LED should

turn blue while the button is depressed.

3. Release the RESET button, and the LED will return to

green status.

10

EZ-Light™ UV Option

A UVPhotoMAX™ is capable of powering an optional single Ultravation

®

T3™

Germicidal UV lamp to keep HVAC internal surfaces clear of mold which re-

duces airborne mold allergen and helps minimize HVAC energy consumption.

The EZ-Light™ option may be advisable in the southern regions or where

there is a constant demand for air conditioning. Heavier use frequently leads

to bacterial/mold fouling of AC equipment. In these cases it may be beneficial

to add a 3rd lamp for items such as blower motor assemblies or turning vanes.

Stand-alone Ultravation

®

UltraMAX™ Germicidal UV light kits are available.

We recommend that this unit be installed and maintained by a trained HVAC

professional technician. Consult your HVAC service provider or call 1-866-468-8247

for more information.

Installation Steps (If EZ-Light was purchased separately see instruction

for connection to UVPhotoMAX accompanying EZ-Light.)

1.

Select location for UV lamp. Drill a 1" hole. Install mounting plate over

drilled hole with the provided screws. Insert UV lamp module into hole.

Attach to HVAC system with two provided self-tapping screws.

2.

Plug the rubber lamp connector fully onto the installed UV lamp assembly.

Be sure the four pinholes are oriented to match the four pins on the lamp

(see diagram pg. 11).

Notes:

The rectangular pin pattern allows connection in two positions (see diagram pg. 11).

A UV status viewport lens is supplied to verify lamp operation. Drill a 3/8" hole within a 3"
radius around the lamp, and on the “lamp side” of the “V” in the light shield (if used), to
accommodate installation of the viewport.

9

Lamp Replacement

The UV lamp is shipped installed in the equipment and should be replaced

during an annual service. To replace the UV Lamp follow the steps below:

Important Information About UV Lamp Replacements

Replace UV lamps at each annual service in order to maintain optimum

effectiveness in the reduction of pathogens such as bacteria, viruses and

microscopic mold. Lamps operating beyond one year do not provide

adequate reduction of pathogens and must be replaced. Lamps operating

beyond two years draw excessive electrical current which may result in

damage to the UV system. If UV lamp(s) have been operating for more than

two years, the system must be turned off until replacement lamp(s) are

installed. Failure to do so may void the warranty.

1. Unplug power cord

and remove power

module. See Fig. 1.

2. Note the position of

the Photon Clarifier

and pull adjustment

bar to its full-out

position. See Fig. 2.

3. Remove lamp screws

and pull lamp out of

PCO module.

See Fig. 3.

4. Install new lamp and

fasten with lamp

screws.

5. Return the Photon

Clarifier to its noted

setting.

6.

Place the power

module on the unit

and fasten.

7.

Plug in power cord.

Fig. 1

Fig. 2

Fig. 3

Warranty

Ultravation

®

UVPhotoMAX™ features a ten-year warranty, with the exception

of the ultraviolet lamp(s), which are warranted for a period of one year after
date of consumer purchase.

This warranty does not include damage to the unit from accident, misuse or
improper installation.

If this product should become defective, Ultravation will elect to repair or
replace the product free of charge. Ultravation will return repaired or replaced
warranted products pre-paid to the customer, provided that the product was
delivered pre-paid.

Ultravation shall have no responsibilities for charges incurred by the
customer for installation or removal of warranted items. Liability is limited
only to the replacement or repair of this product.

This warranty gives you specific legal rights, and you may also have other
rights, which vary from state to state. All returns must be accompanied by a
return authorization number, which may be obtained by contacting
Ultravation, Inc.

Ultravation, Inc.

Phone: 1-866-GO-UV-AIR (468-8247)
www.ultravation.com • [email protected]

Ultravation.com

UL Listed. The health aspects associated with the use of this
product and its ability to aid in disinfection of environmental
air have not been investigated by UL.

5TA2

Ultravation’s T3™ system is protected by US patents 6,809,326B2 and 6,838,057B2 • Copyright © Ultravation, Inc. All rights reserved.

11

The screw holes on the UV lamp must
to be parallel to the lamp lead cord on
the back of the female receptacle for
correct assembly!

Lamp Lead
(rubber sleeved
female receptacle)

Lamp screw
holes and lamp lead
cord need to be parallel

Horizontal orientation of the lamp
lead requires installing the lamp
with screws left to right.

Note that lamp pin pattern is NOT square.

It can be mounted from either side and top
or bottom depending on the orientation of
the installed lamp.

EZ-Light UV Option Diagram

UVC Lamp