Maintenance:

The pleated filter media in your air cleaner must be
changed periodically. The frequency of filter
replacement is best determined by visual examination.
However, a bi-annual replacement of the 5” filter is
strongly recommended. Replacement filters may be
obtained through your installing contractor or local
dealer. - Actual replacement may vary depending on
the severity of dust and dirt particles.

If the Photocatalytic aluminum filter should become
dirty, it may be cleaned with low velocity
compressed air or vacuum only, no solvents or
water should be used
. If the Photocatalytic section
becomes wet, allow the section to air dry before
reinstallation.

The aluminum mesh screen on the Photocatalytic filter
is coated using a patented process known to photo
chemically breakdown VOC’s and Odors as well as
reduce airborne pathogens on contact. Under normal
operating conditions this filter should last up to 10
years.
.
The Air cleaner should never be run with less than a
MERV-11* Filter.

Using less than a MERV-11* Filter rating will reduce
the effectiveness of this product. It is recommended
that this product be serviced and maintained by an
HVAC professional.

*MERV or Minimum efficiency rating value is a number
assigned to filters indicating their ability to capture
particles and dust, the higher the number the better the
filter. A MERV 11 filter is 40% more effective than a
MERV-8. Be sure that an Ultravation MERV-11 filter is
requested for replacements in this product.

Steps for replacing filters:

Pleated Media Filter:

1. Open the access door by Turning knob until

catch releases and then pulling toward you and
lifting up removing door completely.

2. Remove pleated filter and discard.

3. Slide new filter into cabinet with “airflow label

pointing in the direction of the airflow. Be sure
to seat new filter into top and bottom guide rails
to assure a good seal.

4. Replace access door.

Note: a gasket is provided to seal between the opening
on the side of the filtration cabinet and the side of the
air handler.

Aluminum PCO Filter:

1. Open the access door by lifting up then pulling

toward you to remove door completely.

2. Remove aluminum filter and discard

3. Slide new Aluminum PCO filter into cabinet

after media air filter in direction of airflow. Be
sure to seat the new filter into both top and
bottom guide rails to assure a good seal.

4. Replace access door.



Advertising