Brother PJ-600 Series Command Reference

19

© 2011 Brother Industries, Ltd. All Rights Reserved.

Name

Bidirectional transmission mode

Syntax ESC

+

~

+ e + D + {n1}

1B H + 7E H + 65 H + 44 H + {n1}

Description When bidirectional transmission is enabled, the printer returns the “printing completed”

status when printing is finished. In addition, if an error occurred during printing, all print

data received for those pages is discarded.

Definition of {n1}:

0: Disable (default)

1: Enable

*Replies with a “status information request” command even if bidirectional transmission

is disabled.

Name Set

density

Syntax ESC

+

~

+ d + {n1} + null

1B H + 7E H + 64 H + {n1} + 00 H

Description Specifies the print density.

Note: Print density may differ from the conditions, such as the type of thermal paper,
print pattern, environment, etc. Please set the appropriate density.

Definition of {n1}: 0 to 255

The lower the parameter value, the lower the density becomes.

Parameter n1

Density amount

0 (00 H) ~ 23 (17 H)

0

24 (18 H) ~ 47 (2F H)

1

48 (30 H) ~ 71 (47 H)

2

72 (48 H) ~ 95 (5F H)

3

96 (60 H) ~ 119 (77 H)

4

120 (78 H) ~ 143 (8F H)

5

144 (90 H) ~ 167 (A7 H)

6

168 (A8 H) ~ 191 (BF H)

7

192 (C0 H) ~ 215 (D7 H)

8

216 (D8 H) ~ 239 (EF H)

9

240 (F0 H) ~ 255 (FF H)

10

Advertising