JC; Reviewed:
SPOC 9/14/2010

Solution & Interoperability Test Lab Application Notes

©2010 Avaya Inc. All Rights Reserved.

5 of 16

PlantronicsC620

4.1. Configure Station for Avaya IP Softphone or Avaya one-X

Communicator

Use the add station n command; where n is an available extension in the dial-plan. To create a
station to be used by Avaya IP Softphone or Avaya one-X Communicator, the following
information should be provided:

Type: The IP Telephone type that will be emulated. In this compliance testing, the type

was set to 2420.

Security Code: Password used by Avaya IP Softphone or Avaya one-X Communicator

to log in.

Port: Set to X to administer the station without hardware.

IP SoftPhone?: y

add station 10023 Page 1 of 6
STATION

Extension: 10023 Lock Messages? n BCC: 0
Type: 2420 Security Code: 12345 TN: 1
Port: X Coverage Path 1: COR: 1
Name: IP Softphone Coverage Path 2: COS: 1
Hunt-to Station:
STATION OPTIONS
Time of Day Lock Table:
Loss Group: 2 Personalized Ringing Pattern: 1
Data Option: none Message Lamp Ext: 10023
Speakerphone: 2-way Mute Button Enabled? y
Display Language: english Expansion Module? n

Survivable COR: internal Media Complex Ext:
Survivable Trunk Dest? y IP SoftPhone? y

IP Video Softphone? n

Customizable Labels? Y

Advertising