P-touch Template 2.0 Command Reference

- 42 -

7. Control Command Details

^RC

Specify line feed command text string

ASCII: ^

R

C

n1

n2

data

Decimal: 94

82

67

nd1

nd2

datad

Hexadecimal: 5E 52 43 nh1 nh2 datah

Parameters

0≤n1≤2

0≤n2≤9

00h≤datah≤FFh

Description

Specifies the text string for the line feed command.

(n1*10)+n2: Length of the text string (can be set between 1 and 20)

data:

Text string (The maximum number of characters that can be set is 20 characters (bytes).)

The default text string for the line feed command is “^CR”.

This command is a dynamic command.

Remarks

Invalid if more than 20 characters have been specified

Example

To change the text string for the line feed command to “0Dh 0Ah”:

Since the text string to be specified (data) contains 2 characters, n1=0 and n2=2. Therefore, the command

will be as follows.

^ R C 0 2 0Dh 0Ah

(5Eh 52h 43h 30h 32h 0Dh 0Ah)

Advertising