Esc ixd1 retrieve delimiter, Esc ixd1, Retrieve delimiter – Brother RJ-4030 User Manual

Page 85

Advertising
background image

P-touch Template 2.0 Command Reference

- 79 -

7. Control Command Details

ESC iXD1 Retrieve delimiter

ASCII: ESC

i

X

D

1

n1

n2

Decimal: 27

105

88

68

49

nd1

nd2

Hexadecimal: 1B 69 58 44 31 nh1 nh2

Parameters

nh1: 00h (Fixed)

nh2: 00h (Fixed)

Description

Retrieves the text string specified for the delimiter.

3- to 22-byte data is returned from the printer. (Varies depending on the length of the text string)

[1,2]:

nh1 nh2 (number of characters) nh1+(nh2*256)

[3 and later]: Text string

The retrieved value is a value specified by a static command.

Example

When the delimiter is set as “,” (2Ch):

Code: ESC i X D 1 00h 00h

(1Bh 69h 58h 44h 31h 00h 00h)

Returned value: 01h 00h

(01h 00h 2Ch)