The following applies when using tankless water heaters to recover a storage tank.
Drawing WH-1-B is an example.

Tankless water heaters have a pressure loss which must be

considered in the system design.

Reference the pressure loss curve for the heater model being used to determine the pump size for the

desired recovery rate.

For recommended pump sizes use the table below. Additional pressure losses in plumbing between the
Heater(s) and the storage tank must also be taken into consideration.

The specified pump size is to provide maximum recovery of the storage tank. A smaller pump size may
be used, but could result in longer recovery time of the tank. Please contact the Tech Services department
with any questions on pump sizing.

NOTE:

Only use pumps of brass or stainless steel construction. Do not use pumps of iron
construction as they will oxidize and clog the inlet filter on the appliance.

Pump Sizing for Storage Tank Application

7

Pump Flow Requirements

Number of

Tankless

Water Heaters

705/505

305

1

6 gpm @ 30' head

5 gpm @ 25' head

2

12 gpm @ 30' head

10 gpm @ 25' head

3

18 gpm @ 30' head

15 gpm @ 25' head

4

24 gpm @ 30' head

20 gpm @ 25' head

5

30 gpm @ 30' head

25 gpm @ 25' head

6

36 gpm @ 30' head

30 gpm @ 25' head

7

42 gpm @ 30' head

35 gpm @ 25' head

8

48 gpm @ 30' head

40 gpm @ 25' head

9

54 gpm @ 30' head

45 gpm @ 25' head

10

60 gpm @ 30' head

50 gpm @ 25' head

11

66 gpm @ 30' head

55 gpm @ 25' head

12

72 gpm @ 30' head

60 gpm @ 25' head

13

78 gpm @ 30' head

65 gpm @ 25' head

14

84 gpm @ 30' head

70 gpm @ 25' head

15

90 gpm @ 30' head

75 gpm @ 25' head