Connect an RS-232, GPIB, or LAN Interface to a PC

To connect the signal generator to a PC using an RS-232 interface
(Only for use with Agilent E44xxB ESG Signal Generators)

1. Connect Agilent E44xxB ESG signal generators to the PC as shown in the following diagram. Use a 5-mm nut driver to

remove both standoffs (screws) from the female-female adapter.

RS-232 communications are connected to one of the COM ports on the PC using an RS-232 serial cable with a
null-modem connected between the COM port and the signal generator’s RS-232 connector. Refer to the

“RS-232

Installation Kit (Only for use with Agilent E44xxB ESG Signal Generators)” on page 7

for more information.

NOTE

Ensure that the selected COM port is not used by any other device while
PSG/ESG Upgrade Assistant 5.12 is being used.

2. Set the RS-232 parameters as follows on the Agilent E44xxB ESG signal generators:

a. Press the following keys:

Preset (factory defined)

Utility > GPIB/RS-232

RS-232 Baud Rate > 19200

RS-232 Echo > Off

RS-232 Pace >

Transmit Pace > None

Receiver Pace > Xon

RTS/CTS > RTS On