Model PT-1650

1. Parameter Settings

Set settings for bar code.

A. Protocol

Specify protocol.



Code 39



UPC-A



Code 128



EAN8



EAN128



EAN13



CODABAR



I-2/5



UPC-E

B. Width

Specify width of bar code graphic.



Small



Medium



Large

C. Under Number

Specify whether the number is printed
under the bar code.



On



Off

D. Check Digit

Code 39, I-2/5 and CODABAR only,
specify Check Digit on/off.



On



Off

1. Style

Set font style.



Normal



Italic



Bold



Italic + Bold



Outline



Italic + Outline

1. Size

Set the size for an individual line.



Auto



4mm



1mm



6mm



2mm



9mm



3mm



12mm

1. Copies



1-99

2. Number

(sequential labels)



Off



1-99

3. Block No.

Choose the block numbers (start/end)
to print.

4. Mirror

(print text in reverse order)



Off



On

C

Co

om

mm

mo

on

n F

Fu

un

nc

cttiio

on

ns

s &

& C

Co

om

mm

ma

an

nd

ds

s

1. Cut



1 (1 = cut-pause; no chain print)



2 (2 = no cut-pause; no chain print)



3 (3 = cut-pause; chain print)



4 (4 = no cut-pause; chain print)

2. Contrast



+ 2 to –2 ( 0 = default,

+

= darker,

= lighter)

3. Auto Reduction

If label is set to AUTO size, text size
or width will change based on label
length.



Text Size



Text Width

4. Length Adjustment

Increase or decrease the label length
if the length differs from actual.



+3 to -1, 0 = default

5. Symbol Save

Personal Category is full, symbols
will be added (on) or not (off).



On



Off

6. Units

Set unit for measurement.



inch



mm

7. Language

Set language for menus, settings
and messages.



English



Français

8. Version Info

Version information for P-touch
software & symbol set.



Main



Boot



Char-Set (Character Set)



Symb-Set (Symbol Set)

1. Length

Specify label length.



Auto / 0.30 - 39.00inch

(Auto / 6 - 999mm)

2. Margin

Specify margin.



0.10 - 4.00inch (2 - 99mm)

Setup

Menu

(Line)

Style

(Line)

Size

Format

(Label)

Length

Print

Options

Label

Type

Bar Code

Functions

(Label)

Frame

(Label)

Clear

Bar Code

1. Bar Code

Type in bar code data.

1. GLB (Global) Size

Set font size for label.



Auto



1mm



2mm



3mm



4mm



6mm



9mm



12mm

2. GLB (Global) Wide

Set label font width.



Minimum



Narrow



Normal



Wide

3. GLB (Global) Style

Set label font style - individual line
style overrides settings.



Normal



Bold



Outline



Italic



Italic + Bold



Italic + Outline

4. Align

Specify text alignment.



Left



Justify



Right



Center

1. Frame

Choose from 14 different borders.



Off



1 – 14

1. Clear

Clear text (and font) to start new label.



Text & Format



Text Only

1. Label Type

Specify type of label printed.



Normal



Rotate



Rotate-Repeat



Port



Panel



Flag



Vertical

®

(Label/

Database)

Transfer

Search

Data

Insert

Space

Insert

Printed in China LN5676001A

1. Transfer

Transfer a database or template.

With PT-1650



Turn Machine OFF with



Press and Hold
simultaneously



Release



Release

With PC and PT-Editor



Open PT-Editor on PC



Open templates/database to be
transferred



Verify printer is set to PT-1650 with

File ... Printer Setup command



Access the File Transfer screen with
File ... Transfer Template



For each template file to be
transferred

• Click on the template file [may

be attached to database] in list

• Choose a PF key to transfer to

by clicking on Change PF key

Mapping and selecting the PF

key from pull down list



Click Start, to transfer files

On PC, select Exit to exit out of
transfer program.

On P-touch, press to turn
machine off. Press to turn
machine on.

Use PF key (you have assigned)
to access transferred template (to
directly access database, see
Data below).

1. Data

Scroll through a transferred database.



- Scroll columns



- Scroll rows

1. Search

Search through a transferred
database. Database must be opened
with .



Type in characters (case

dependent).

to start.

©2003 Brother International Corporation, 100 Somerset
Corporate Boulevard, Bridgewater, NJ 08807. All rights reserved.
All trademarks and registered trademarks referenced herein are
the property of their respective companies.