Agilent 8590 C/E/L/Q and EM Series Notes

1. For more information please contact your local Agilent sales

representative.

2. 8593 EM only

3. Quasi-peak detection and AM/FM demodulator is standard on 8590

EM-series and has additional capacity compared to Option 103.

4. Programming manual included

5. Options 101 and 102 required for TV sync trigger capability. See

Option 301.

6. 85717A measurement personality required

7. 85719A measurement personality required

8. ABF

Quick reference and user’s guides in French

ABD

Quick reference and user’s guides in German

ABZ

Quick reference and user’s guides in Italian

ABE

Quick reference and user’s guides in Spanish

ABJ

Quick reference guide in Japanese

AB0

Quick reference guide for Taiwan in Chinese

AB2

Quick reference guide for China in Chinese

9. An incremental cost will be added to the base price of Options

W30/W32/W34/W50/W52/W54 for an 859xC/E/L/Q containing
Options 010, 011, or 130.

10. Parts only kits. No installation included. May require new analyzer

firmware.

11. Option 003 (card reader) on the 8590L, 8592L and 8594L is required.

12. For more information on EMC products and configurations see lit. num-

ber 5964-6089E.

13. Refer to measurement personality product literature for required 8590

series option configuration.

14. Except 8591 EM

15. Video tests not supported on 8590L, 8592L or 8594L.

16. Option E51 comes with preamplifier, carrying case, cables and

connectors.

17. Tracking generator retrofit requires factory installation of Option K10.

18. Cable TV measurements are formatted for local country's cable TV

standards.

19. Modulation accuracy measurements not supported on 8591E.

20. Rack height is 8.75 inches.

21. Not for analyzer operation while in carrying case

22. Options 021, 023 and 024 or 041 and 043 cannot be combined.

23. Not compatible with Option 107

24. Not compatible with other demodulator options (102, 103, 110, 112,

or 301).

25. Compatibility with 8591E limited to CDMA applications only

26. Compatible with serial prefixes 3523A or 3525U and higher

27. Compatible with serial prefixes lower than 3523A or 3525U

28. If Options 009 and 010 are combined on the 8593E/94E/95E/96E or

8590 EM series; only one option card slot is required.

29. Not compatible with Options 101 and 301

30. Requires Option 111. Not compatible with 8591E.

31. NTSC Cable TV analyzers only

32. Option 107 is not compatible with Option 180.

33. 85721 Cable TV measurement personality required

34. 11770A Link measurements personality required. Do not order Option

010 with Option 111.

35. Option 160 and 163 are not compatible.