Tripod mount

Orientation locking knob

5. Infinity Compensation Mark

To compensate for shifting of the infinity focus point that results

from changes in temperature.

The infinity position at normal temperature is the point at which the

vertical line of the L mark is aligned with the distance indicator on

the distance scale.

• For accurate focusing in MF on subjects at infinity distance, look

through the viewfinder while rotating the focusing ring

.

6. Hood

To attach the hood, align the hood’s attachment position mark

with the red dot on the front of the lens, then turn the hood in the

direction of the arrow until the lens’s red dot is aligned with the

hood’s stop position mark

.

The hood can be reverse-mounted on the lens for storage.

• Part of the picture may be blocked if the hood is not attached

properly.

7. Filters (Sold Separately)

You can attach filters to the filter mounting thread on the front of

the lens.

• Use a polarizing Canon filter (77mm).

8. Switching the Focusing Distance Range (EF70-

200mm f/2.8L USM Only)

You can set the focusing distance range to 1.5 m/4.9 ft. to infinity or

3m/9.8 ft. to infinity

.

• If you use AF from outside the specified focusing distance range,

the lens may stop focusing when it reaches the limit of the range.

This is not a malfunction. If this occurs, press the shutter button

halfway down again.

9. Extenders (Sold Separately: EF70-200mm f/2.8L USM

Only)

AF is possible with Extender EF1.4× II/EF2× II.

• The aperture F values and focal lengths when an extender is used

are as follows:

EF1.4× II: f/4, 98-280mm, EF2× II: f/5.6, 140-400mm

Attach the extender to the lens, and then attach the lens to the

camera. To remove it, reverse the order. Errors may occur if you

attach the extender to the camera first.

When you are using an extender, use the center focusing point for

AF. If you use AF with a different focusing point, a focusing error

may occur.

10. Using the Tripod Mount (EF70-200mm f/2.8L USM

Only)

By loosening the orientation locking knob on the tripod mount you

can rotate the camera to set the image for any vertical or horizontal

position.

Detaching the Tripod Mount

First remove the lens from the camera and then remove the tripod

mount from the lens as shown below. To attach the tripod mount,

reverse the procedure.

1) Loosen the orientation locking knob



.

2) Align the red mark on the tripod mount with the lens mount

index



.

3) Slide off the tripod collar away from the rear of the lens



.

n

The lens length is measured from the mount surface to the front

end of the lens. Add 21.5 mm to include the E-77U lens cap and

dust cap, and 24.2 mm for the E-77 II.

n

The size and weight listed are for the lens only, except as

indicated.

n

Aperture settings are specified on the camera. The camera

automatically compensates for variations in the aperture setting

when the camera is zoomed in or out.

n

All data listed is measured according to Canon standards.

n

Product specifications and appearance are subject to change

without notice.

This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Do not make any changes or modifications to the equipment
unless otherwise specified in the instructions. If such changes
or modifications should be made, you could be required to stop
operation of the equipment.
This equipment has been tested and found to comply with the limits
for a class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and receiver.

• Consult the dealer or an experienced radio/TV technician for help.

This Class B digital apparatus complies with Canadian ICES-003.

Specifications

Angle of view

Lens

construction

Minimum

aperture

Max. magnification and field of view

Min. focusing

distance

Filter diameter

<Usable number>

Max. diameter

and length

Weight

Hood

Case

Diagonal

Vertical

Horizontal

EF17-35mm f/2.8L USM

104°-63°

70°30’-38°

93°-54°

10-15

22

0.06 -0.11Ч 432 Ч 671 mm -214 × 320 mm
(17” Ч 26.4”-8.4” Ч 12.6”)

0.42 m

77 mm <1>

83.5 × 95.7 mm
(3.3” × 3.8”)

545 g

(19.1 oz)

EW-83 CII

LP1216

EF28-70mm f/2.8L USM

75°-34°

46°-19°30’

65°-29°

11-16

22

0.08 -0.18Ч 298 Ч 452 mm -133 × 198 mm
(11.7” Ч 17.8”-5.2” Ч 7.8”)

0.5 m

77 mm <1>

83.2 × 117.6 mm
(3.3” × 4.6”)

880 g

(30.8 oz)

EW-83 BII

LP1219

EF70-200mm f/2.8L USM

34°-12°

19°30’-7°

29°-10°

15-18

32

0.06 -0.16Ч 409 Ч 617 mm -152 × 226 mm
(16.1” Ч 24.3”-6” Ч 8.9”)

1.5 m

77 mm <1>

84.6 × 193.6 mm
(3.3” × 7.6”)

1,310 g

(45.9 oz)

ET-83II

LZ1324

COP