ePowerSwitch 4XM

High Security ePowerSwitch

with IP device and

environmental monitoring

„

Multiple concurrent users

Allows multiple concurrent user access. Each user has access
to control his designated power outlets.

„

DHCP client

The DHCP option enables to reduce the configuration
management.

„

Scheduler for Time-Controlled Applications

This time-controlled function lets you control Power Outlets and
dry Contacts and also allows to send Emails.

„

IP device monitoring

Enables to monitor IP devices using PING and Scan functions
with automatic reboot in case of lock-up of the monitored
device.

„

Temperature and Humidity monitoring

This function lets you monitor temperature and humidity in
racks or server rooms.
If thresholds are exceeded, Power Outlets and dry contacts
can be automatically controlled and Email and Syslog
messages sent.

„

Improved log file reporting

Event logs are written to the log file and can be sent to a
primary and a secondary Syslog Server.

„

Programmable Labels

A 32-character label can be attributed to the ePowerSwitch and
to each power outlet to avoid confusion during operation.

„

Easy Configuration

Full configuration can be performed through the Web using the
Web GUI.
The network settings can also be done via a convenient tool or
a Terminal connection.

Features

„

Remote Power Management

Each power outlet can be turned On/Off or restarted over
IP

.

„

Redundant power supply for the web server

To improve the security the ePowerSwitch 4XM supports
dual Power Inputs. The web server can be supplied either
through the main power input or through an auxiliary
power adapter.

„

Power Outlet Grouping

Enables to group individual outlets. Ideal to control
redundant power supply servers & devices with a single
command.

„

Sequential power up/down

Avoids the risk for a power in-rush to blow a fuse or circuit
breaker in the data centre.

„

Restart Delay

This delay, which applies to the restart activity at all
power outlets, can be chosen between 1 and 65535
seconds (> 18 h) between off/on.

„

Access and accounts

The administrator password allows configuration and
control of all power outlets. The administrator also can
create up to 16 user accounts with access rights only to
designated outlets.

„

Advanced Security

For your security, account access and data transfer can
be encrypted with SSL Technology.

ePowerSwitch 4XM is an enhanced power distribution and control unit that enables remote power management of 4
devices over Ethernet.
This high security device can use the HTTPS protocol and also includes IP device and environmental monitoring
functionalities. It supports HTTP, HTTPS, DHCP, Syslog, SNMP, SMTP and SNTP protocols. An internal clock allows
to timestamp syslog messages, e-mails and internal logs.