3192

4-Pair LPU

P/N: 1181501L2

CLEI: SIPQ0CVF_ _

3192 4-Pair Line Power Unit

LPU

POWER

UNDER VOLTAGE

GROUND FAULT

OVERLOAD

UNDER CURRENT

1181501L2

*61181

501L2-

22C*

INSTALLATION

After unpacking the unit, inspect it for damage. If damage is noted, file a claim with
the carrier, and then contact ADTRAN. For more information, refer to the warranty.
The LPU installs in any two adjacent slots in a 3192 shelf.

WARNING: Adhere to static discharge precautions when handling circuit cards.

To insert the LPU, perform the following steps:

1. If present, remove the blank panel from the appropriate module slot of the

chassis.

2. Pull the ejector latch, located on the lower right-hand side of the LPU front panel,

from its closed position.

3. Hold the LPU by the front panel while supporting the bottom edge of the module

with the ejector latch opened to engage the chassis edge.

4. Align the LPU card edges to fit in the lower and upper guide grooves for the

access module slot.

5. Slide the LPU into the module slot. Simultaneous thumb pressure at the top

(above the

POWER

LED) and at the bottom (below the electrostatic caution

symbol) of the front panel ensures that the LPU is firmly positioned against the
backplane of the chassis.

6. Secure the LPU in place by pushing in on the ejector latch.

Upon installation, the LPU initiates a self-test. Once the power up self-test is
completed, the front panel LEDs reflect the true state of the hardware.

GENERAL

This job aid provides information for the installation, function, and operational use of
the ADTRAN

®

3192 Line Power Unit (LPU). The LPU (P/N 1181501L2) is designed

to provide power for the Total Access

®

1124/1148 Line Powered Digital Subscriber

Line Access Multiplexer (DSLAM).

DESCRIPTION

Each ADTRAN LPU provides up to 100 watts of power to an associated DSLAM on
a one-to-one basis. The LPU can reside either in a Central Office (CO) or be installed
in a remote facility in close proximity to the associated DSLAM. The LPU provides

±145 VDC power and can span distances up to 60 kft (approximately 11 miles).
Each LPU occupies any two adjacent slots in a 3192 shelf. Slots not occupied by an
LPU can house standard channel cards. Total slot population is limited by the

maximum input current of the 3192 shelf.
The LPU receives –48 VDC at a maximum of 2.6 amps from the chassis backplane
and outputs to four Tip and Ring power pairs. Voltage potential per pair is Tip +145

VDC and Ring –145 VDC (290 VDC combined).
The total power wiring pair requirement is based on transmission distance to the
remote location.

FUSES

Power input to the LPU is fused at 4.0 amps; Tip and Ring power output is fused at

1.5 amps each. Fuses are not replaceable.

LED INDICATION

Five front panel LEDs provide status for the LPU. The

POWER

LED is green; its

normal condition is on. All other LEDs are red; their normal condition is off. LEDs
are as follows:

LED

Status Description

POWER

On

Off

LPU receiving –48 VDC
LPU not receiving power or supply fuse failed

UNDER VOLTAGE

On

Off

< 115 VDC per T or R (< 230 VDC per T/R pair)
Voltage normal: ±145 V per T/R (± 5%)

GROUND FAULT

On

Off

Ground fault detected
No ground fault

OVERLOAD

On

Off

> 0.4 amps at 290 VDC
No overload

UNDER CURRENT

On

Off

< 0.04 amps
Current normal

61181501L2-22C