Connections

DUCTING VERSION AIR EXHAUST SYSTEM

When installing the hood in ducting version, a rigid or a
flexible pipe with the diameter corresponding to the
flange diameter is used in order to connect the hood to
the air outlet piping.


• Fix the pipe with an adequate quantity of pipe

clamps (not supplied).

• Remove possible charcoal filters.

RECIRCULATION VERSION AIR OUTLET

• Cut a hole ø 125 mm in any shelf that may be posi-

tioned over the hood.

• Insert the flange 10a on the hood body outlet.
• Connect the flange to the outlet on the shelf over the

hood using a flexible or rigid pipe ø120 mm.

• Fix the pipe in position using sufficient pipe clamps

(not supplied).

• Fix the directional grille 8 on the recirculation air

outlet using the 2 screws 12e (2,9 x 12,7) provided.

• Ensure that the activated charcoal filters have been

inserted.

12e

8

ELECTRICAL CONNECTION

• Connect the hood to the mains through a two-pole switch having a contact gap of at least 3

mm..