Pro1100, Manual temperature controls, Description – AquaPRO PRO1300 User Manual

Page 6: Indicator lights, Water temperature set point

Advertising
background image

Operating Instructions

www.aquaprosystems.com

Manual Temperature
Controls

Description

• The manual Temperature Control is

designed to regulate pool and spa
water temperature.

• There are two indicator lights on the

control panel to display the current
status of the unit.

• The thermostat knob may be

adjusted to maintain the desired
water temperature.

Indicator Lights

• There are two indicator lights on the

front panel that display unit status. The
GREEN light indicates that power to the
unit is on. The RED light indicates that
the unit is in heating mode.

Phone: (877)-278-2797

4

Figure 4 - PRO1100 wiring diagram

PRO1100

• The RED light may become

illuminated prior to heater start up.
The RED light will become lit when
the thermostat knob is set at or
above the water temperature.

The unit has a built in time delay.

Every time the unit turns off there is a
five-minute time delay until the unit
may be restarted.
The HEAT light may
turn on during this delay cycle. Do not
rotate the thermostat knob during this
time delay. Rotating the knob during
this cycle may reset the time delay,
causing the unit to wait an additional
five minutes prior to startup.

Water Temperature Set Point

• Temperature set point range is 45°F

to 107°F. Rotating the thermostat
knob clockwise will increase the
temperature set point, while rotating

counterclockwise will decrease the
temperature set point.

• A floating thermometer may be

placed in the pool or spa to monitor
water temperature.

• To initially calibrate the thermostat to

the desired set point, turn the
thermostat knob fully clockwise. The
unit will turn on and begin heating
after a possible five minute time delay.
Allow the unit to run until pool or spa
water reaches the desired temperature.
Slowly turn thermostat knob counter-
clockwise until the unit turns off. The
unit will now maintain this water
temperature, providing the circulation
pump is running.

Fan

Motor

Green

Light

Red

Llight

240V-24V

Transformer

Capacitor

Compressor

Thermostat

Time

Delay

Water

Pressure

Low

Pressure

High

Pressure

Black

Black

Black

Black

Black

White

Brown/ White

Brown

Blue

Blue

Blue

Blue

Blue

Yellow

Yellow

Gray

Gray

Gray

Gray

Red

Red

Orange

Nuet Hot In Out

T2 T1

Contractor

L2 L1

Line Line

Temp

1 2

TB1

3 4

C

F H

C

R

S

PRO1100

Advertising