Note, Charcoal filter replacement, Remove the vent grill mounting screws – Bosch HMV3062U User Manual

Page 20: Pull the vent grill away from the unit, Change the charcoal filter

Advertising
background image

20

6.

Remove old light bulb and replace only with equivalent

30 watt bulb available from parts distributor. Bulbs are

also available at most hardware stores or lighting

centers.

Note: DO NOT USE BULB LARGER THAN 30 WATTS.

7.

Replace the microwave oven light cover by carefully

pushing into place. Replace the charcoal filter. Push

the vent grill back into place (engaging both the

bottom and top tabs) and replace the vent grill

mounting screws

Charcoal filter replacement
The charcoal filter, which was enclosed with your

microwave oven, is used for nonvented, recirculated

installation (Room Venting). The filter should be changed

every 6 to 12 months depending on use.

1.

Disconnect power to the microwave oven at the circuit

breaker panel or by unplugging.

2.

Remove the vent grill mounting screws.

3.

Pull the vent grill away from the unit.

4.

Change the charcoal filter.

5.

Carefully push the vent grill back into place and

replace the screws removed in Step 2.
Note: If no charcoal filter is installed, it is not possible

to bind the odorous substances in the cooking

vapours.