English 4

The maximum depth of cabinet installed above cooktop
is 13” (33cm).

NOTE:
All measurements given have to be precisely followed. If
nonstandard cabinets are used, make sure they are
installed with minimum dimensions shown in figure 1 and
figure 2.

Plan the installation of the unit so that the power cord, gas
shut-off valve and gas pressure regulator are accessible
from the front of cabinet.

Countertop Requirements

Island Installation

Mounting Requirements

Use the mounting brackets supplied. See “Install the
Cooktop” on page 5 for further details
.

Ventilation Recommendations

We strongly recommend the installation of a ventilation
hood above this appliance. The hood must be installed
according to instructions furnished with the hood.

Figure 1:

Installed Dimensions (from cooktop edges

)

Depth from Back Wall

Cabinet 13" (33cm) max.

Hood Depth - 24" (61cm) max.

Centered Over Cooktop

Rear Wall - 2" (5cm)

Right Side

12" (33cm) min.

Left Side

12" (33cm) min.

18" (46cm) min.

Above Counter - 30" (76 cm) min. to

Combustible Surface

NGM30 - 30" (76cm) min.
NGM36 - 36" (91cm) min.

Figure 2: Cutout Dimensions

gas

connection

measurement in inches/mm

30” Models

36” Models

gas

connection

measurement in inches/mm

2 1/8”

(54)

3”

(76.2)

3”

(76.2)

3 1/8”

(79.4)

measurement in inches/mm

Front

Back

Advertising