background image

15

* If a rectangular-to-round transition adapter is used, first

make sure the damper hinge of the microwave swings

freely. If necessary, cut the damper to fit, using the tin

snips, in order to allow free movement.

Equivalent lengths of duct pieces are based on actual

tests and reflect requirements for good venting

performance with any vent hood.

Testing Operation

1.

Turn on power at the breaker.

2.

Test the microwave:
Place a cup of water into the oven cavity. Follow the

instructions in the Use and Care Manual on how to

heat a beverage.

3.

Verify that the oven light comes on and the water is

heated.

4.

If any of the tests do not result as explained above,

contact service for assistance. Otherwise, the

installation is complete at this time.

45° Elbow

5 ft (1.5 m)

x

=

90° Elbow

25 ft (7.6 m)

x

=

45° Elbow

5 ft (1.5 m)

x

=

Roof Cap

24 ft (7.3 m)

x

=

Straight Duct 6" (152 mm

Round or 3 1/4" x 10"

(82 x 254 mm) Rectangular

1 ft (0.3 m)

x

=

Duct Pieces

x

Number used

=

Equivalent Length

Total Ductwork =